Hydrostatic Test for Kitchen Suppression Systems

Hydrostatic Test for Kitchen Suppression Systems

Kitchen suppression systems are designed, tested, and approved to provide fire protection for commercial kitchen cooking appliances, hoods, and ducts. The suppression systems consist of an agent storage tank, manual release station, an automatic releasing mechanism, and supply piping that directs the agent to nozzles strategically positioned at heat sources in the kitchen. 

Kitchen’s hood suppression system includes a tank which contains the wet chemical suppression agent. Hydro testing is when that tank is removed from service and taken in for testing. 

The wet chemical storage tank, whether pre-pressurized or non-pressurized, will be emptied of the chemical suppression agent, then filled with water or oil. It will then be sealed and pressurized to two to three times its operating pressure, and it will be kept at that pressure for at least one minute. If the pressure holds, the tank has passed the hydro test. 

If the tank passes the test, it will be cleaned out and refilled with suppression agent to be put back in service. If it is a non-pressurized system that uses a cartridge, such as Ansul systems, then the cartridge must also be hydro tested or replaced at that time. 

Additionally, during this time, many companies like SSA Integrate will also replace your hood suppression system’s hoses as well. 

NFPA 17 requires that every 12 years the agent-holding tank, whether it is a pressurized or non-pressurized system tank, must be pulled out of service to be tested. But pre-pressurized systems have DOT requirements, requiring that the first test occur after 12 years, but then every 7 years after that, as they can weaken and lose their pressure over time. 

For all systems, the agent storage tank must be pressure tested to ensure the integrity of the cylinder. There are many types and manufactures of kitchen commercial wet chemical systems, each one has different test pressures for the cylinder, which are set by the manufacturer. Once filled with water, and sometimes oil, the cylinder is capped off, then pressurized to the manufacture test pressure and held at that pressure for no less than 1 minute. These systems are often tested to almost two times the service pressure.

On a non-pressurized system, there is a cartridge that pushes the agent out of the cylinder. This cartridge is replaced every 12 years. In some instances, these systems can have a burst disc that would need to be replaced before the 12-year hydrostatic test is scheduled.

Pressurized systems have valve stems, O-rings, and pins that need to be replaced. This is called a rebuild kit. Once all of the cylinders are tested, dried, and documented they get filled back up with the proper wet chemical agent and put back into service if there is not any issues with the test pressures. All systems, both pressurized and non-pressurized, get new agent during a 12-year hydrostatic test. For certain suppression systems, hoses will need to be replaced at the 12-year hydrostatic test.

Inspections, tests, and maintenance on kitchen ventilation hoods and fire suppression systems shall be performed in accordance with the manufacturer's instructions, NFPA 17 (latest edition), 17a (latest edition), 72 (latest edition), and NFPA 96 (latest edition). 

Monthly inspections are an important tool to ensure that your system stays in good working order. But inspections do not eliminate the need for routine maintenance of your system. NFPA 17A requires a full inspection of your system at least twice a year (semiannually) and after any activation.

Like your monthly inspections, these inspections must follow the manufacturer’s guidelines. However, they are much more comprehensive and detailed in nature and as such, require more time and expertise than monthly inspections do. At minimum, these inspections require the following:

An evaluation of your system from a hazard perspective – Has the hazard changed in any way that might make the system less effective?

An examination of every component of your system – This includes your fire detectors, the containers that hold the extinguishing agent, your system’s releasing devices, piping, hose assemblies, nozzles, and signals as well as any auxiliary equipment.

A check of the agent distribution piping throughout your system – are there any obstructions that might prevent the release and/or proper flow of extinguishing agent?

An examination of the wet chemical in your system – If there is any evidence of corrosion or pitting or structural damage to the cylinders, the chemical may not feed properly through your distribution system and should be replaced and the system recharged.


Monthly and annual maintenance tags shall be attached to each fire suppression system for recording the inspector’s initials, date, and confirmation on maintenance/inspections performed. Where fusible links are used, the manufacture and the installation dates for the links shall be marked on the system inspection tag. In addition, a signed and dated log of maintenance and a certificate showing date of exhaust system inspection or cleaning shall be available in the food service manager’s office and the facility manager’s office.

ITEM

ACTIVITY

FREQUENCY

NFPA REF

Extinguishing system nozzles are located directly above grease producing equipment

Inspection

Monthly

17A:7.2.2

17:11.2.1.1

The Manual actuators are unobstructed

Inspection

Monthly

17A:7.2.2,

17:11.2.1.1

The tamper indicator’s and seals are intact

Inspection

Monthly

17A:7.2.2

17:11.2.1.1

The maintenance tag or certificate in place

Inspection

Monthly

17A:7.2.2

17:11.2.1.1

No obvious physical damage or condition exists that might prevent operation

Inspection

Monthly

17A:7.2.2

17:11.2.1.1

The pressure gauge(s) are in operable range.

Inspection

Monthly

17A:7.2.2

17:11.2.1.1

The nozzle blow-off caps are intact and   undamaged.

Inspection

Monthly

17A:7.2.2

17:11.2.1.1

Neither protected equipment nor hazard has been replaced, modified, or relocated

Inspection

Monthly

17:11.2.1.1

17A: 7.2.2

Gas and electric power shutoff are operational

Test

Semiannually

17:11.3.1.4

Water-wash hood cleaning systems are operational in conjunction with hoods   protected by sprinkler systems

Test

Semiannually

96:11.2.1

Remove grease from exhaust system

Maintenance

Quarterly/ Semiannually

96 :11.3,

96 :11.4,

Recirculating systems operation and safety interlocks perform in accordance with mfg’s instructions

Test

Every 6 mos or more frequently

96:13.6.5

Recirculating systems.  Electrostatic Precipitators cleaned

Maintenance

Weekly

96:13.6.3

Recirculating systems.  Clean entire hood Plenum and blower section.

Maintenance

Quarterly

96:13.6.4

Fixed temperature sensing elements of the fusible alloy type

Replace

Annually

17:11.3.2,

17A:7.3.3,

96:8.2.1.2

Clean fixed temperature sensing elements other than the fusible metal alloy type

Maintenance

Annually

17:11.3.3

17A:7.3.4

Manual release stations are operational and send a signal to the building fire alarm control panel.

Test

Semiannually

17:11.3.1.4

17A:7.3.2.3

Automatic release devices are operational and send a signal to the building fire alarm control panel.

Test

Semiannually

17:11.3.1.4

17A:7.3.2.3

Water flow, valve tamper, and low water pressure cut-offs are operational

Test

Quarterly

72: Table

7-2.2 - 13i

Examine detectors, expellant gas containers, agent containers, releasing devices, piping, hose assemblies, nozzles, signals, and all auxiliary equipment

Maintenance

Semiannually

17:11.3.1.

17A:7.3.2.3

Verify that the agent distribution piping is not obstructed

Test

Semiannually

17:11.3.1

17A:3.2.1

Examine dry chemical in stored pressure systems for caking

Inspection

Every 6 years

17:11.3.1

Hydrostatic pressure test on wet and dry chemical extinguishing systems (agent containers, aux. pressure containers, hose assemblies)

Test

Every 12 years

17:11.5.1

17A:7.5.1


Ref:
NFPA 17 (latest edition), 17a (latest edition), 72 (latest edition), and NFPA 96 (latest edition).

Sunday, August 2, 2020

Why UL listing important

Why UL listing important

Standards are all around us, even if we are not always aware of them. One example of a widely-used standard is the A4 size for sheets of paper.
A standard is a document that sets out requirements for a specific item, material, component, system or service, or describes in detail a particular method or procedure. Standards facilitate international trade by ensuring compatibility and interoperability of components, products and services. They bring benefits to businesses and consumers in terms of reducing costs, enhancing performance and improving safety.
Standards are developed and defined through a process of sharing knowledge and building consensus among technical experts nominated by interested parties and other stakeholders - including businesses, consumers and environmental groups, among others.
UL” is short for Underwriters Laboratories, an organization which has been testing and approving products for consumer safety since 1894. Originally known as the Underwriters Electrical Bureau, UL was founded in Chicago by William Merrill, and has since expanded to include 182 service centers in more than 70 countries. Underwriters Laboratories performs safety testing on 18,750 categories of electrical, mechanical and chemical products. So, UL a third-party certification company that’s been around for over a century.
When it comes to UL certification. Certifying products within your business can get expensive, fast. However, one thing that’s never worth skimping on is safety. Your customers’ and workforce’s safety are the most important thing to ensure brand loyalty. Safety and reliability can be the difference between long-term success and catastrophic failure.

UL markers are most commonly seen on industrial equipment and home appliances. These include furnaces, fuses, electrical panels, fire control panel, circuit breakers, cameras, smoke and CO2 alarms, fire extinguishers, sprinklers, glass, and thousands of low voltage equipment. UL Listing in this case means that the product is compliant with the American National Electrical Code (NEC), and is therefore regarded as "safe", i.e., not prone to electrical faults or failures which may cause damage to equipment, facilities, or people.

If your surveillance or safety equipment is not UL listed, it can be ripped out. Technically speaking, cameras and other low-voltage devices do not require UL listing, as they fall under the limited power source (LPS) category. Products in this category do not require listing themselves. Instead, the power source, whether it be a low-voltage supply, midspan, or PoE switch, is to be listed. In practice, however, inspectors often do not follow this, requiring the UL mark other products, as well.

In the surveillance industry, UL listing varies. Many mainstream brands are UL listed. However, it may not apply to every camera in their portfolio, with some lower-cost or SMB/SOHO product being unlisted. Others have only listed the current generations of their equipment. Finally, many lower-cost brands are completely unlisted, limiting their use in some jurisdictions. Users should be aware of these variances when selecting product, and make no assumptions.

In the safety industry, UL listing must be in Detector, Fire Control Panel, MCP, Module, sprinkler, Pump etc. Some OEM follow EN listing of said item for safety i.e., not prone to electrical faults or failures which may cause damage to equipment, facilities, or people.
Listing can generally be found on data sheets, normally in an "approvals" section, though not always. Sometimes it is found only in installation manuals, and other times users must contact the company to get listing information. All these variables make UL compliance a tedious process.
While 'UL Certification' implies electrical safety, the actual standard number it satisfies varies.
For surveillance gear, there are below certification standards that address different safety aspects:
  • UL 60950: Is the most common for cameras, and applies to low voltage safety (ie: non combustibility)
  • UL 1492: Audio/Video Products and Accessories
  • UL 1995: Heating and Cooling Equipment
  • UL 2802: Tests related to performance quality of Camera image quality.
  • UL 2043: Standard for Fire Test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces.
  • UL 60065: Audio, Video and Similar Electronic Apparatuses: Safety Requirements
For Life Safety gear, there are below certification standards that address different safety aspects:
·        UL 217: Single- and Multiple- Station Smoke Alarms
·        UL 268: Smoke Detectors for Fire Protective Signalling Systems
·        UL 268A: Smoke Detectors for Duct Application
·        UL 294: Standard for Access Control System Units
·        UL 1023: Standard for Household Burglar-Alarm System Units
·        UL 1610: Standard for Central-Station Burglar-Alarm Units
·        UL 864: Standard for Control Units and Accessories for Fire Alarm Systems
·        UL 1626: Residential Sprinklers for Fire Protection Service
·        UL 1971: Signalling Devices for the Hearing Impaired
·        UL 1741: Inverters, Converters, Controllers and Interconnection System Equipment for Use with Distributed Energy Resources


For Wire and Cable gear, there are below certification standards that address different safety aspects:
·        UL 62: Flexible Cords and Cables
·        UL 758: Appliance Wiring Material (AWM)
·        UL 817: Cord Sets and Power Supply Cords
·        UL 2556: Wire and Cable Test Methods

 

Someone is shopping for a new circuit breaker or contactor; UL certification might sway their decision. If two identical products or services are side-by-side and one is UL certified and one isn’t, which one would you likely choose? It’s been shown that the UL mark can be a powerful marketing tool for businesses, and so many of them strive to get their products approved. The UL logo gives the consumer peace of mind, and the business a public seal of approval.
Whether the UL mark is required on all electrical parts in an installation varies tremendously, depending on the municipality, and even between different inspectors. We have seen various requirements for listing, in different municipalities:
  • No UL listing required: Some municipalities are extremely lenient, never checking any product for UL certification. 
  • Ceiling-mounted products: One of the most arbitrary requirements we have seen is that all ceiling-mounted equipment must be listed, but no other parts of the system were checked. 
  • High-voltage only: In other cases, only high-voltage products require UL listing. This means that electricians are required to comply, but low-voltage security equipment is exempt. 
  • Strict, 100% listing: In the most extreme cases, the building inspector will require every last part of an installation to bear the UL mark, whether it be servers, cameras, cable, or any other components. 
These variations, and others, are why we suggest users should check with their AHJ before installation. In some cases, bids and RFPs may also provide requirements for UL certification, taking the guesswork out of the process.
Since the level of compliance required may vary significantly, it is recommended that users check requirements with the authority having jurisdiction before installation takes place, or even before furnishing estimates.
If unlisted products are being used, but the inspector requires certification, users have two options:
  1. Replace the non-compliant product with compliant. This is often the simplest way to gain compliance. The major downside is, of course, that product must be removed and replaced, incurring additional material, shipping, and labor costs.
  2. Contract UL to provide a one-time certification of the system of the whole. In this case, a UL engineer visits the site and performs testing of the system in place. While this may alleviate listing issues, it is extremely expensive, commonly in the $10,000+ range for even small installations. It is therefore considered a last resort.
UL Certification allows a company to innovate its safety standards and align themselves with industry-wide best practices. Being UL certified illustrates a businesses’ dedication to consumer safety, as well as the quality of their products. Another important caveat of UL certification is for insurance purposes and customer security.

Why is this important? If, say, an inspector determines a fire was caused by a circuit breaker that was not UL certified, an insurance company can choose to deny the claim. For this reason alone, many consumers opt for certified products, not just for large appliances but for small ones as well as laptop and cell phone chargers. UL certification adds a layer of protection and accountability for accidents, as well. UL is a third-party service; consumers of your products can be confident that the UL seal is not a superficial sales ploy. Instead, it’s a true indication of an item’s safety and longevity. It protects brand’s reputation by having an established certification company standing behind what you sell. Remember if you use UL product due to some malfunction you decided to repair your device / panel. Then you must involve said product OEM/ authorised professional. Do not repair through technician / engineer / repairing centre, if you do then UL listing is void. It assumed as zero safety. In case further malfunction or electrical hazard happened then OEM are not responsible for it.
So, don’t immediately assume your products aren’t safe just because it doesn’t have a UL certification. It’s never a bad idea, however, to seek out UL certification when designing into new electronics and appliances.
Even if it might cost a bit more for your business or take extra testing time, UL gives a consumer the peace of mind and a brand a big marketing boost. In the long run, third-party certifications from a trusted source will only help your business. UL Certifications have the ability to add accountability and enhance your brand’s reputation over time.
Hopefully, now you feel a bit more familiar with that little UL logo and have a better idea of what it means and why it’s important for you and your business. When manufacturers are UL certified is shows their continued commitment to safety and quality.
Ready to upgrade your home or workplace with UL certified parts and products? Shop our full assortment of devices, switches, and other electronics.

In the fire alarm and life safety industry, UL (Underwriters Laboratories) is the "gold standard" for reliability. Without it, you are essentially guessing if a life-saving device will work when a building is on fire.

Fire Detection & Signaling System - UL

Product Short Name

UL Standard

Letest Edition

Brand

Model

 Fire Alarm Control Panel 

UL 864

10th

Edwards

EST4  and EDGE

Notifier

INSPIRE  and ONYX Series

Simplex

4100ES, 4010ES, 4007ES

Morley-IAS

STX and SMX Series

Kentec

Taktis

Smoke Detector (Commercial Systems)

UL 268

7th

Edwards

SIGA-OSD

Notifier

FSP-951 Series

Simplex

4098-9754, 4098-9714, 4098-5601

Morley-IAS

HM-PSE-UL-W

Kentec

KSU-OPT-7

Smoke Alarm (Residential Alarms)

 UL 217

8th

Kidde

20SAR (Hardwired), P3010k-CO

First Alert  / BRK

ZCOMBO (Z-Wave), SA304CN3 (with Escape Light), PRC700 (Slim Profile)

Heat Detector

UL 521

8th

Edwards

SIGA-HRD, SIGA-HFD, 281B-PL, 282B-P, SIGA-PHS.

Notifier

FST-951,FST-951R, FST-951H and FST-851, FST-851R

Simplex

4098-9733, 4098-9734, 4098-9754, 4098-9401 / 9402

Morley-IAS

MI-HSE-S2-IV/WH, MI-RHSE-S2-IV/WH, MI-HTSE-S2-IV/WH

Kentec

ATJ-EA, ATG-EA, 55000-400APO, ACC-V

Notification Appliances - hooters, horns, sirens, and bells.

UL 464

 11th

Edwards

EG1-HDVM, EG1H-HDVM, G4AVRF, G4LF Series, 757 Series (Integrity), 860 Series

Notifier

P2RL / P2WL, HRL / HWL, PC2RL / PC2WL, HWL-LF / HRL-LF, P2R / P2W

Simplex

49AO-WRF / 49AO-WWF, 49HF-WRF / 49HF-WWF, 4901-9820

Morley-IAS

System Sensor L-Series, P2RL / P2WL, HRL / HWL, HRL-LF / P2RL-LF

Kentec

GEC3-24WR, P2RL / P2WL, HRL-LF, ASBL-LF,

Notification Appliances - Speakers

UL 1480

7th

Edwards

Genesis LED GCS Series, Genesis GC Series, Genesis G4 Series, 757 Series

Notifier

System Sensor L-Series, SPSWL-LF / SPSRL-LF, SPRK / SPWK,

Simplex

49SO-WRF / 49SO-WWF, 49SOP-WRF / 49SOP-WWF, 49SOC-WRF / 49SOC-WWF

Morley-IAS

System Sensor L-Series, SPSWL-LF / SPSRL-LF, SPRK / SPWK,

Kentec

System Sensor L-Series, SPSWL-LF / SPSRL-LF, SPRK / SPWK,

Notification Signaling Devices for the Deaf and Hard of Hearing

UL 1971

3rd

Edwards

Genesis LED Series, Integrity Series

Notifier

System Sensor L-Series,

Simplex

TrueAlert ES Series

Morley-IAS

System Sensor L-Series,

Kentec

System Sensor L-Series,

Visible Notification  Signaling Devices

UL 1638

6th

Edwards

Genesis Series, Integrity Series

Notifier

SpectrAlert Advance,  System Sensor L-Series,

Simplex

TrueAlert ES Series,  4906-9101

Morley-IAS

SpectrAlert Advance,  System Sensor L-Series,

Kentec

SpectrAlert Advance,  System Sensor L-Series,

Visible Notification  Signaling Devices

UL 1971

3rd

Edwards

Genesis LED (EG1/G4)

Notifier

System Sensor L-Series

Simplex

TrueAlert ES

Morley-IAS

MI-HSR / MI-HSW

Kentec

System Sensor L-Series

Manual Signaling Boxes . MCP , MPS

UL 38

8th

Edwards

SIGA-278 and SIGA-270

Notifier

NBG-12LX

Simplex

4099-9005

Morley-IAS

System Sensor M400K, MI-MCP or F/MCP

Kentec

DCP-AMS

Control, Relay, and Monitor modules.

UL 864

11Th

Edwards

SIGA CT1, SIGA CC1, SIGA CR, SIGA CT2, SIGA MM, SIGA IM

Notifier

FRM-1, FCM-1, FMM-1

Simplex

4090-9001, 4090-9002, 4090-9008, 4090-9117, 4090-9116, 4007-9801

Morley-IAS

HM-D240CMO-UL

Kentec

DCP-FRCME-M, DCP-FRCME-4, DCP-SOM-A, DCP-SCI, K758

Power Supplies

UL 1481

5Th

Edwards

3-BPS/M, 4-PPS/M

Notifier

AMPS-24 / AMPS-24E, HPF24S6 / HPF24S8, FCPS-24S6 / FCPS-24S8

Simplex

4100-5125 / 5126, 4905-9929, 4009-9201 / 9301, 4009-9401

Morley-IAS

 

Kentec

 

 Ref: