Sunday, March 3, 2019

Recent Fire in Bangladesh Reminds Put Safety First

Recent Fire in Bangladesh Reminds Put Safety First

It happens on Bangladesh or Barlin or India it always tragic – it remained us “Safety First”. NFPA was saddened to learn of the recent tragic fire that swept through Dhaka, Bangladesh claiming the lives of nearly 70 people and injuring scores more. While a specific cause for what started the fire has yet to be determined, we do know that the intensity and spread of the fire stems from the storage of chemicals in the midst of the mixed-use part of the old city combining residences, shops, and unfortunately, chemical storage warehouses. (We don’t know specifically what chemicals were involved, but news accounts have mentioned flammable gas, flammable or combustible liquids like solvents or similar volatile materials, and have alluded to perfumes, cosmetics, and simple combustibles.)

What is particularly troubling is that a similar incident occurred in Dhaka in 2010. While the event was followed by a government effort to prohibit chemical storage in the city center, the effort was not sustained because it lacked a commitment of all involved parties tasked with protecting people and property. Such collaboration is at the root of what NFPA calls the Fire & Life Safety Ecosystem, a concept that helps guide all affected stakeholders through the process for identifying fire, life safety, electrical, and related hazards, and creating solutions to manage such hazards. Right now, this safety system is broken.
Take the 2010 incident in Bangladesh. While the process began with government recognition of the hazard, it needed more than just a push from government to build the framework. By way of example, according to the Ecosystem concept, full adherence to the codes and the referenced standards within would provide the process for storing chemicals in designated areas away from the public; an informed and skilled workforce would better be able to identify and respond to dangerous actions (i.e. the movement of stored chemicals from a once designated separate place back to residential areas); and an informed public would be more vocal and diligent in encouraging change in the name of safety. 
We are reminded that what we have seen with this incident in Bangladesh has happened elsewhere in the world:  In the U.S. in 2013, an ammonium nitrate fertilizer plant explosion killed 15 people; in China in 2016, a fire and explosions devastated a warehouse area storing chemicals and killing 170 people. In each of these incidents, the governments’ ill informed decisions related to zoning and compliance with existing fire and life safety codes and standards contributed to the devastating outcomes.  
So, what do the standards say about chemical storage and how they could have applied in Dhaka? NFPA standards, such as NFPA 1, NFPA 30, and NFPA 400, would approach these hazards by ensuring the following:
•    Identifying the hazard classification and characteristics
•    Identifying the types of containers used for storage
•    Limiting the quantities of the more volatile materials
•    Using construction to manage some of the storage (separate buildings or structures for certain materials to keep them segregated from incompatible materials) and enforcing separation distances from other structures, people and public areas
In the days to come, additional facts about this recent incident in Bangladesh will come to light. As we learn more, let it be a reminder that change can and should take root not just in Bangladesh but across the world. And while there is no single solution to fire and life safety, we believe that engaging in a full safety systems approach, as illustrated in the Fire & Life Safety Ecosystem concept, will get us closer to solving the world’s fire problem.  
At NFPA, we continue our focus on the entire safety system, working with professionals around the globe in support of the development and use of the Ecosystem concept in their countries and according to local cultures. By working together, recommitting to, and promoting this full system of fire prevention, protection and education, we can help save lives and reduce loss.
আগুন, যার একটাই গুণ- কেবল জ্বালাতেই জানে। এবং এই অগ্নিক্ষুধা এতোটাই একপাক্ষিক ঘটনা যে, জান-মাল সহ কিছুই আর অবশিষ্ট রাখে না। প্রতিবছর আমাদের দেশে আকস্মিক অগ্নিকাণ্ডে কী পরিমাণ জান-মালের ক্ষতি হয় তার কোন পরিসংখ্যানমূলক তথ্য হাতের কাছে না থাকলেও নাগরিক জীবনে এর ভয়াবহতা ও ভিকটিম হিসেবে আমাদের অসহায়তার অন্ত নেই। বাসা-বাড়ি অফিস-আদালত থেকে শুরু করে মার্কেট-বহুতল ভবন যান-বাহন ইত্যাদি প্রায় সকল ক্ষেত্রে অগ্নি নির্বাপক সিস্টেমের অভাব বা অপ্রতুলতা এবং আমাদের ভয়ানক অজ্ঞতা-অসচেতনতার কারণেযেকোন সময় যেকোন স্থানে যে কেউ এই আগ্রাসী অগ্নিকাণ্ডের দুঃখজনক ট্র্যাজেডির অসহায় শিকার হয়ে যাওয়া বিচিত্র নয়। গ্রামে-গঞ্জে বা ছোটখাটো শহরগুলোতে হুট করে বাইরে খোলা জায়গায় বেরিয়ে পড়ে প্রাণ বাঁচানোর ছোট্ট সুযোগটুকু পাওয়া গেলেও খাঁচাবদ্ধ নাগরিক জীবনে সেটাও সুদূরপরাহত বলেই মনে হয়। তাই প্রতিমুহূর্তের সমূহ আশঙ্কা আর সম্ভাব্য বিপদ মাথায় নিয়েই আমাদের নাগরিক জীবন।
ইদানিংকালে ঢাকার কিছু অগ্নিকাণ্ডের ঘটনা-উত্তর পরিস্থিতি থেকে আমাদের দুঃখজনক অভিজ্ঞতা হচ্ছে, আগুনে পুড়ে মরার চাইতে বহুগুণ বেশি মৃত্যু ঘটে হুড়োহুড়িতে পদপিষ্ঠ হয়ে। বিশেষ করে কিছু গার্মেন্টস ফ্যাক্টরির অনাকাঙ্ক্ষিত অগ্নিকাণ্ডের ঘটনায় আমরা তা লক্ষ্য করলাম। আবার নিমতলীর ভয়াবহ অগ্নিকাণ্ড যে আমাদেরই বালখিল্য অসতর্কতা ও অবিবেচনাপ্রসূত অসচেতনতার ফসল তাও বলার অপেক্ষা রাখে না। এতে করে আগুনের তীব্রতার চাইতেও আমাদের অজ্ঞতা-অসচেতনতাই অধিক তীব্র বলে অনুমিত হয়। এছাড়া বহুতল ভবনগুলোর অন্ধ-আবেগি নির্মাণশৈলিতে প্রয়োজনীয় বিল্ডিং কোড অমান্যের পাশাপাশি অত্যাবশ্যকীয় অগ্নি-নির্বাপক ব্যবস্থার শোচনীয় ঘাটতি বা অনুপস্থিতি, আমাদের রাষ্ট্রিয় ফায়ার সার্ভিস ও সিভিল ডিফেন্স সংস্থার যুগোপযোগী প্রয়োজনীয় ইকুইপম্যান্ট সার্ভিস না থাকা, বিশেষ করে তেরো তলার উপরে অগ্নিনির্বাপণে তাদের অসহায় অক্ষমতায় (যা এফ আর টাওয়ার অগ্নিকাণ্ডে লক্ষ্য করা গেছে) বহুতল ভবনশীর্ষবাসীদের স্রেফ অদৃষ্ট-নির্ভর হয়ে যাওয়া ইত্যাদি বিষয় আমাদের নাগরিক-যোগ্যতাকেই প্রশ্নের সম্মুখীন করে তুলেছে। এমতাবস্থায় আগুন সম্পর্কে আমাদের সতর্ক সচেতনতার কোন বিকল্প চোখে পড়ে না। একটু সচেতন হলেই আমরা অনেক বড় বড় দুর্ঘটনা থেকে পরিত্রান পেয়ে যেতে পারি। অনেক ভয়ঙ্কর ট্র্যাজেডিরও দুর্ভাগা সাক্ষি হতে হয় না আমাদের। আসুন না, আমরা সে চেষ্টাটুকুই করতে পারি কিনা দেখি।

২০১৯ সালের ২০ ফেব্রুয়ারি বাংলাদেশের ঢাকায় চকবাজারে অগ্নিকাণ্ডের ঘটনা ঘটে। সেখানে একটি গ্যাস সিলিন্ডারের বিস্ফোরণ হতে সৃষ্ট আগুন পার্শ্ববর্তী ভবনসমূহে ছড়িয়ে পড়ে এবং বৈদ্যুতিক ট্রান্সমিটার বিস্ফোরিত হয়ে এলাকাটি বিদ্যুৎ-সংযোগবিচ্ছিন্ন হয়ে যায়। দমকল বাহিনী পাঁচ ঘণ্টার চেষ্টায় আগুন নিয়ন্ত্রণে আনতে সক্ষম হলেও (সরকারি হিসাব মতে) ততক্ষণে ঘটনাস্থলে অগ্নিদগ্ধ হয়ে ৭৮ জন মারা যান।

কারণ

শিল্প মন্ত্রণালয়ের প্রাথমিক তদন্ত প্রতিবেদনে বলা হয়, ২০ ফেব্রুয়ারি রাত ১০টা ৩৮ মিনিটে রাজধানীর পুরান ঢাকার চকবাজার থানার চুড়িহাট্টা মসজিদ সংলগ্ন আসগর লেন, নবকুমার দত্ত রোড ও হায়দার বক্স লেনের মিলনস্থলে একটি প্রাইভেটকারের সিলিন্ডার বিস্ফোরণের মাধ্যমে অগ্নিকাণ্ডের সূত্রপাত হয়। সেই আগুনে প্রাইভেটকারের কাছেই থাকা গ্যাস সিলিন্ডারবাহী একটি পিকআপের সিলিন্ডারসমূহও বিস্ফোরিত হয়; বিস্ফোরিত হয় পার্শ্ববর্তী খাবার হোটেলের গ্যাস সিলিন্ডার এবং রাস্তার বৈদ্যুতিক ট্রান্সমিটারও। পুরো এলাকা বিদ্যুৎ-বিচ্ছিন্ন হয়ে পড়ার মধ্যেই আগুন ছড়িয়ে পড়ে নিকটস্থ রাজ্জাক ভবন, হাজী ওয়াহিদ ম্যানশনসহ পাঁচটি ভবনে। হাজী ওয়াহেদ ম্যানশনে থাকা পারফিউমের গুদাম ও অন্যান্য দোকানে রাখা প্লাস্টিক গ্রেনুলারসমূহ দাহ্য পদার্থ হিসেবে আগুন ছড়িয়ে পড়তে সাহায্য করে। আরেকটি ব্যাখ্যা অনুসারে, মোড়ে থাকা একটি বিদ্যুতের ট্রান্সফরমার থেকে আগুনের সূত্রপাত হয়। পরবর্তীতে বিস্ফোরক পরিদপ্তরের করা তদন্ত প্রতিবেদনে বলা হয়, ওয়াহেদ ম্যানশনের দ্বিতীয় তলায় রাখা সুগন্ধির ক্যানগুলো থেকে কোনো কারণে বাতাসে বিস্ফোরক মিশ্রণ তৈরি হয়েছিল। বৈদ্যুতিক স্ফুলিঙ্গ ওই মিশ্রণের সংস্পর্শে এসে বিস্ফোরণ ঘটে অগ্নিকাণ্ডের সূত্রপাত হয়। প্রতিবেদনটিতে সিলিন্ডার বিস্ফোরণে আগুনের সূত্রপাত হওয়ার বিপক্ষে যুক্তি তুলে ধরা হয়েছে।

ঘটনাক্রম

ঘটনাস্থলে অগ্নিদগ্ধ গাড়ি ঘনবসতিপূর্ণ ও সরু গলিপথের পুরান ঢাকায় দ্রুত আগুন ছড়িয়ে পড়ে; নিকটস্থ এক কমিউনিটি সেন্টারে বিয়ে উপলক্ষে সড়ক ছিল জনসমাগমপূর্ণ। আগুনে পথচারী ও রিকশাযাত্রীরাসহ ভবনগুলোর বাসিন্দারা অগ্নিকাণ্ডের শিকার হন। এর মধ্যে দমকল বাহিনীর ১০টি ফায়ারস্টেশনের ৩৭টি ইউনিট অগ্নিনির্বাপনের কাজ শুরু করে; ৪টি হেলিকপ্টারের মাধ্যমে আগুনলাগা ভবনগুলোতে পানি ছিটানো হয়। রাত ৩টার দিকে আগুন মোটামুটি নিয়ন্ত্রণে আসে, তবে এরপরেও ছোটোখাটো বিস্ফোরণ হতে থাকে। পরদিন ২১ ফেব্রুয়ারী দুপুর ১টায় ১৫ ঘণ্টাব্যাপী অগ্নিনির্বাপণ অভিযান সমাপ্ত ঘোষণা করা হয়।

হতাহত

দমকলবাহিনী ঘটনাস্থল থেকে ঢাকা মেডিকেল কলেজে ৭০টি লাশ প্রেরণ করে; আরো ১১টি লাশ বিভিন্নভাবে এসে পৌঁছায়। এছাড়া আহত অগ্নিদগ্ধ ৫২ জনের মধ্যে ৪১ জন প্রাথমিক চিকিৎসা নেন এবং ১১ জনকে হাসপাতালে ভর্তি করা হয় এবং হতাহতদের বেশির ভাগ লোক নোয়াখালি জেলার।

ক্ষয়ক্ষতি

অগ্নিকাণ্ডে একাধিক হোটেল ও দোকানসহ পাঁচটি ভবন সম্পূর্ণ পুড়ে যায়। পুড়ে যাওয়া ওয়াহিদ ম্যানশন ধ্বসে পড়ার সম্ভাবনা জানান বুয়েটের প্রকৌশলীগণ। এছাড়া ৪টি গাড়ি, ১৫টি মোটরবাইকসহ অনেকগুলো রিকশা, ভ্যান ও ঠেলাগাড়ি অগ্নিদগ্ধ হয়।

প্রতিক্রিয়া 

অগ্নিকাণ্ডে হতাহতের ঘটনায় রাষ্ট্রপতি আবদুল হামিদ ও প্রধানমন্ত্রী শেখ হাসিনা শোক প্রকাশ করেন এবং প্রধানমন্ত্রী উদ্ধার কার্যের তত্ত্বাবধান করেন বলে জানান ঢাকা দক্ষিণ সিটি কর্পোরেশনের মেয়র সাঈদ খোকন। বিরোধীদল বিএনপি অগ্নিকাণ্ডের জন্য 'সরকারের অব্যবস্থাপনা'কে দায়ী করে এবং ২৩ ফেব্রুয়ারী শোকদিবস পালনসহ দুদিনের কর্মসূচী ঘোষণা করে।
অগ্নিকাণ্ডে হতাহতদের স্বজনদের তথ্য জানাতে বিশেষভাবে হটলাইন চালু করা হয়।
অগ্নিকাণ্ডে আহতদের চিকিৎসার খরচ সরকার বহন করবে বলে জানান স্বাস্থ্যমন্ত্রী জাহিদ মালেক। পাশাপাশি শ্রম মন্ত্রণালয় থেকে নিহত শ্রমিকদেরকে ১ লক্ষ এবং আহতদেরকে ৫০ হাজার টাকা করে আর্থিক সহায়তা দেয়া হবে বলে জানানো হয়।
মেয়র সাঈদ খোকন পুরান ঢাকায় আর কোনো রাসায়নিক গুদাম রাখতে দেয়া হবে না এবং কঠোর পদক্ষেপ নেয়া হবে বলে জানান। পুলিশ মহাপরিদর্শক জাবেদ পাটোয়ারী জানান যে রাসায়নিক গুদাম সরাতে সংশ্লিষ্ট দপ্তরকে পুলিশ সহায়তা দিতে প্রস্তুত আছে। তবে 'অর্থনৈতিক প্রবাহ' বজায় রাখতে পুরান ঢাকার রাসায়নিক ব্যবসা বন্ধ করা যাবে না বলে মন্তব্য করেন শিল্পমন্ত্রী নুরুল মজিদ মাহমুদ হুমায়ূন। অগ্নিকাণ্ডের কারণ অনুসন্ধান, ক্ষয়ক্ষতি নিরূপণ ও ভবিষ্যতে অগ্নিকাণ্ড রোধে শিল্প মন্ত্রণালয়ের অধীনে ১২ সদস্যের একটি তদন্ত কমিটি গঠন করা হয় এবং একটি প্রাথমিক প্রতিবেদন জমা দেয়া হয়।
২৫ ফেব্রুয়ারি, সোমবার এক দিনের রাষ্ট্রীয় শোক পালন করা হয়।
আগুন দ্রুত প্রজ্জ্বলনশীল পদার্থের রাসায়নিক বিক্রিয়াবিশেষ। আগুন জ্বালানোর জন্য তিনটি উপাদানের প্রয়োজন পড়ে  - অক্সিজেন,  জ্বালানী এবং তাপ। জ্বালানী হিসেবে কাঠ, কয়লা, তৈল এবং অন্যান্য দাহ্য পদার্থ পরিবেশের সর্বত্র রয়েছে। একবার আগুন জ্বলতে শুরু করলে পরবর্তীতে এটি নিজেই তাপ উৎপাদনে সক্ষম। কখনো কখনো এটি নিজেই স্বয়ংক্রিয়ভাবে তাপ উৎপাদনের মাধ্যমে জ্বলতে শুরু করে।

সাবধানতার সাথে আগুন না জ্বালালে এটি মারাত্মক প্রতিক্রিয়া ও প্রভাব সৃষ্টি করে। একবার আগুন নিয়ন্ত্রণের বাইরে চলে গেলে এটি ১৭,৪০০বর্গ কিলোমিটার এলাকাব্যাপী ক্ষতিসাধন করতে সক্ষম যা মার্কিন যুক্তরাষ্ট্রের নিউইয়র্ক শহরের সমান। বনাঞ্চলের পুরোটাই ধ্বংস হয়ে যেতে পারে যদি তা নিয়ন্ত্রণে রাখা না যায়। প্রতিবছর ইউরোপের বনাঞ্চলের একটি বড় অংশ ধ্বংস হয়ে যায় অগ্নিজনিত কারণে। এ ধরনের ঘটনাগুলো মূলতঃ গ্রীষ্মকালেই সংঘটিত হয়ে থাকে। অগ্নিনির্বাপককর্মী বা প্রশিক্ষিত জনগোষ্ঠী আকস্মিকভাবে সৃষ্ট অগ্নিকাণ্ড বন্ধের জন্য প্রাণান্তকর চেষ্টা চালায় কিংবা আগুনকে নিয়ন্ত্রণে রাখতে সচেষ্ট হয়।
আগুনকে তিনটি পৃথক উপায়ে নির্বাপণ করা সম্ভব। নিচের তিনটির যে-কোন একটি সহায়ক উপাদানকে দূরে সরিয়ে রাখার মাধ্যমে তা সম্ভবপর -
·         যদি আগুনকে তার সাহায্যকারী জ্বালানী এবং অপরাপর জ্বালানীকে দূরে রাখা যায়, তাহলে আগুন জ্বলবে না।
·         অক্সিজেন প্রত্যাহারের মাধ্যমে আগুন নিভানো সম্ভব যা শ্বাসরোধকারী আগুন নামে পরিচিত। আগুন খালি জায়গায় জ্বলতে পারে না অথবা এটি কার্বন ডাইঅক্সাইড দ্বারা আবৃত থাকাবস্থায় জ্বলে না।
·         তাপ শক্তিকে দূরে সরিয়ে রাখার মাধ্যমে আগুনকে নিয়ন্ত্রণে রাখা যায়। সবচেয়ে প্রধান ও সাধারণ উপায় হচ্ছে জল ব্যবহার করা যা আগুনকে বিস্তৃত ঘটাতে সাহায্য করে না।
কিন্তু ম্যাগণেসিয়ামজনিত শিখার সাহায্যে সৃষ্ট কিছু আগুনের সর্বাগ্রাসী বিচ্ছুরণকে আটকানো যায় না। এটি কার্বন ডাইঅক্সাইড, নাইট্রোজেন এবং অন্যান্য অগ্নিনিবারক সহায়ক যৌগকেও পুড়িয়ে ফেলতে সক্ষম।
আগুন নেভানো বা নিয়ন্ত্রণে রাখার জন্য ব্যবহৃত যন্ত্রকে অগ্নিনির্বাপক যন্ত্র বলা হয়। অতি প্রচলিত অগ্নিনির্বাপক যন্ত্রগুলোতে সাধারণত সিলিন্ডারে উচ্চচাপে রক্ষিত তরল কার্বন ডাই-অক্সাইড নজ্‌ল লিয়ে স্প্রে আকারে বের করে আগুন নেভানো হয়। আর CO2.অগ্নি নির্বাপক এক্সটিইংগুইসারঃ যন্ত্রে ধরার জন্য হাতলে একটা বিশেষ জায়গা আছে যেহেতু এই গ্যাস অনেক ঠাণ্ডা তাই অন্য জায়গায় ধরে রাখতে পারবেন না ।
অগ্নিনির্বাপক যন্ত্র / এক্সটিইংগুইসারঃ পরিচালনার সাধারণ ধাপসমূহ হলঃ
1.   সেফটি পিনটি টানুন।
2.   নিরাপদ দুরত্বে থেকে (অন্তত ছয় ফুট দুরে) নজলটি আগুনের মূলে তাক করুন।
3.   হাত দিয়ে নজলটি চাপুন।
4.   অগ্নিনির্বাপক যন্ত্রটি আগুনের দিকে তাক করে একপাশ থেকে আরেক পাশে নাড়ান।
বিভিন্ন ধরনের আগুনের জন্য বিভিন্ন রকমের অগ্নিনির্বাপক যন্ত্র রয়েছে। ভুল রকমের অগ্নিনির্বাপক যন্ত্র ব্যবহারের ফলে আগুন আরও বাড়তে পারে তাই সঠিক ধরনের অগ্নিনির্বাপক যন্ত্র ব্যবহার করা উচিত। আগুন নিভানোর কাজে ব্যবহৃত যে সিলিন্ডারগুলো দেখি তা মুলত ৩ টি ভাগে বিভক্ত।যথাঃ
1) ডিসিপি (DCP)
2) সিওটু(CO2) এবং
3) ফোম জাতীয়(Fome)।
এবার আসুন দেখি কোন এক্সটিইংগুইসারঃ সিলিন্ডার কোন ধরনের আগুনে ব্যবহার করা হয়।
ডিসিপি পুরনাঙ্গ রূপ হচ্ছে ড্রাই ক্যামিকেল পাউডার। এটা সাধারনত কাপড়, পাট, কাঠ, এবং শুকনো কঠিন পদার্থের আগুন নেভানোর জন্য ব্যবহার করা হয়। এই সিলিন্ডার দামি ও সূক্ষ্ম মেশিনের আগুন নেভানোর কাজে ব্যবহার হলে আগুন নিভবে কিন্তু মেশিনগুলো পুনারায় ব্যবহার না করা যেতে পারে। কারন পাউডারের জন্য মেশিনের অভ্যন্তরীণ দামি ও সূক্ষ্ম যন্তারংশ চিরতরে ক্ষতি হতে পারে।
সিওটু (CO2) মানে সহজ বাংলায় কার্বন ডাই অক্সসাইড যেটা দামি ও সূক্ষ্ম মেশিনারিজের আগুন নেভানোর জন্য ব্যবহৃত হয়।ফোম জাতীয় সিলিন্ডার রাসায়নিক, গ্যাসের আগুন নেভানোর কাজে ব্যবহৃত হয়।বাসায় ব্যবহার করার জন্য সিওটু হচ্ছে আদর্শ সিলিন্দার।কারন বাসায় দামি মেশিন যেমন আছে আবার কমদামি শুকনো জিনিসও আছে।
ডিসিপি (DCP) এক্সটিইংগুইসার সিলিন্ডার চেনার উপায় হল এর এই সিলিন্ডারের হজ পাইপটির( সাথে লাগোয়া কালো রঙের নল) পাউডার বেরোনোর দিকটি বেশী বড় থাকবেনা তবে আগার তুলনায় সামান্য চওড়া থাকবে। ডিসিপির নলের মাথা তুলনামূলক চওড়া থাকবে। সংক্ষেপে ৩ টি সিলিন্ডারের ব্যবহার লিখছি।
ক)ডিসিপি (DCP) ফায়ার এক্সটিইংগুইসারঃ এই ফায়ার এক্সটিইংগুইসারের সাহায্যে সাধারনত কঠিন পদার্থের আগুন নিভানো যায়।তবে বিদুতের আগুন,গ্যাসের আগুন ও ছোট ধরনের তেলের আগুনও নিভানো যায়।কার্যক্ষমতার উপর নির্ভর করে।
খ) সিওটু(CO2) ফায়ার এক্সটিইংগুইসারঃ এই ধরনের এক্সটিইংগুইসারের সাহায্যে সাধারনত বৈদ্যুতিক আগুন নিভানো হয়।
গ)ফোম টাইপ ফায়ার এক্সটিইংগুইসারঃ এই ফায়ার এক্সটিইংগুইসারের সাহায্যে সাধারনত তরল পদার্থের আগুন নেভানো হয়। এগুলো আবার দুই ধরনের হয় গ্যাস কার্টিজ টাইপ এবং প্রেসার টাইপ।
প্রতিটি প্রতিষ্ঠান বা সুউউচ্চ বিল্ডিং গুলিতে মাসে একবার নিয়মিত মহড়া হতে হবে । কিছু আগুনের মহড়া হবে না জানিয়ে আর কিছু রাতের বেলায় । মহড়ার লক্ষ্য বিপদের সময় আপনার মাথা কাজ না করলেও শুধু অভ্যাসের বলে কিভাবে সঠিক কাজ করে বের হয়ে আসবেন । যেমন আগুন ছড়িয়ে গেলে কিভাবে দ্রুত বের হয়ে আসতে হবে । কিভাবে ধোঁয়ার নীচ দিয়ে আসবেন ইত্যাদি ।দয়া করে মনে রাখবেনঃ বেরিয়ে যান, বাইরে থাকুন, ফায়ার সার্ভিসকে খরব দিন।

সকল গার্মেন্টস তৈরী ফ্যাক্টরীর একটি অটোমেটিক ফায়ার এলার্ম সিস্টেম থাকতে হবে যা স্বমন্বয় হবে তিনিটি ডিভাইসের মাধ্যমে:
ক) স্মোক ডিটেক্টর (Smoke Detector)
খ) হিট ডিটেক্টর (Heat Detector) এবং
গ) স্প্রিংকলার ওয়াটার ফ্লো ডিভাইস।
স্মোক ডিটেকশন এবং ফায়ার এলার্ম সিস্টেম কোথায় লাগাতে হবেঃ ২৩ মিটার বা ৭৫ ফিট উচ্চতার নিচে যে কোনো বিল্ডিংএ ফায়ার এলার্ম সিস্টেম প্রতিস্থাপন করতে হবে। ২৩ মিটার বা ৭৫ ফিট উচ্চতার অধিক হলে স্প্রিংকলার এবং রশ্মি ডিটেক্টর(Beam Detector) লাগাতে হবে।
স্মোক ডিটেকশন এবং ফায়ার এলার্ম সিস্টেম প্রতিস্থাপনের নিয়মঃ একজন সাপ্লায়ার কে অবশ্যই বি.এন.বি.সি সেকশন-০৪ এর ৪.৪ এবং এন.এফ.পি.এ ৭২ এর গাইড লাইন অনুযায়ি এই সিস্টেম প্রতিস্থাপন করতে হবে।
স্মোক ডিটেকশন এবং ফায়ার এলার্ম সিস্টেম ডিজাইনঃ এন.এফ.পি.এ ৭২ (NFPA 72 2019) এর গাইড লাইন অনুযায়ি একজন সাপ্লায়ার কে এর ডিজাইন তৈরী করতে হবে। একর্ড ফলোআপ অডিট এর সময় এন.এফ.পি.এ ৭২গাইড লাইন অনুযায়ি সম্পূর্ণ সিস্টেম প্রতিস্থাপন করা হয়েছে কিনা তা চেক করা হবে। 

তবে একর্ড এর নিয়মানুযায়ি, স্মোক ডিটেকশন এবং ফায়ার এলার্ম সিস্টেম ডিজাইন প্রতিস্থাপনের পূর্বে একর্ড টিম কর্তৃক পরিক্ষা-নিরীক্ষা করে তাদের কর্তৃক অনুমোদন পূর্বক কারখানায় প্রতিস্থাপনের পরার্মশ দেওয়া হয়েছে। অতএব, কোনো সাপ্লায়ারের কাছে কার্যাদেশ প্রদানের পূর্বে একর্ড কর্তৃক ডিজাইন অনুমোদন পূর্বক তা প্রদান করা উচিত।
উল্লেখ্য যে, স্মোক ডিটেকশন এবং ফায়ার এলার্ম টি কোনো একটি সম্পূর্ণ বিল্ডিং এ একসাথে শুনা জেতে হবে, যেন সকল ফ্লোরের লোকজন একসাথে বিল্ডিং থেকে বেরিয়ে যেতে পারে। আংশিক এলার্ম নোটিফিকেশন কোনোভাবেই গ্রহনযোগ্য নয় এবং উক্ত সিস্টেম থাকলে তা একর্ড নিয়মানুযায়ি পূণরায় প্রতিস্থাপন করতে হবে।


স্মোক ডিটেকশন এবং ফায়ার এলার্ম সিস্টেম প্রতিস্থাপনের পরবর্তী করনীয়ঃ সাপ্লায়ার কর্তৃক প্রতিস্থাপনের পর সম্পূর্ণ সিস্টেম টি এন.এফ.পি.এ ৭২ (NFPA 72 2019) গাইড লাইন অনুযায়ি চেক করতে হবে এবং উক্ত গাইড লাইন অনুযায়ি চেকিং এর সম্পূর্ণ ডকুমেন্টস একর্ড কর্তৃপক্ষের নিকট প্রদান করতে হবে। উক্ত চেকিং ডকুমেন্টস এর উপর ভিত্তি করে একর্ড পূণরায় সিস্টেম টির ফাইনাল টেস্টিং এবং অডিট সম্পন্ন করবে। যদি উক্ত প্রক্রিয়ার কোথাও অসম্পূর্ণ থাকে, তবে একর্ড অডিট ব্যর্থ তথা পুরো পদ্ধতি টি না জেনে স্মোক ডিটেকশন এবং ফায়ার এলার্ম সিস্টেম প্রতিস্থাপনের কঠিন মাশুল দিতে হবে।

এন.এফ.পি.এ ৭২গাইড লাইন অনুযায়ি উক্ত স্মোক ডিটেকশন এবং ফায়ার এলার্ম সিস্টেমটি নিকটস্থ ফায়ার সার্ভিস স্টেশনের সাথে সরাসরি যোগাযোগ স্থাপন করা থাকতে হবে যেন কোনো ধরনের দূর্ঘটনা ঘটার সাথে সাথে নিকটস্থ ফায়ার সার্ভিস স্টেশন জানতে পারে।

কিন্তু যতদিন তা করা সম্ভব না হবে, একজন নিয়োজিত ব্যক্তি উক্ যোগাযোগ রক্ষার জন্য নির্ধারন করা থাকতে হবে। নিয়োজিত ব্যক্তির কর্তব্য স্থলে অবশ্যই সেন্ট্রাল ফায়ার/ স্মোক ইন্ডিকেটর থাকতে হবে।
অফিসের জন্য বা কলকারখানার জন্য প্রয়োজন হয় ইমারজেন্সি অ্যাকশন প্ল্যান। সহজে বের হওয়ার বিকল্প উপায়, ফায়ার ডোর ও আরও বাড়তি কিছু আগুন নেভানোর যন্ত্র যেমন: ফায়ার এক্সটিংগুইশার, স্মোক ডিটেক্টর, ফায়ার ডোর, হাইড্রেন্ট সিস্টেম (জল সরবরাহের উৎস), স্প্রিংকলার সিস্টেম (স্বয়ংক্রিয়ভাবে, অতিরিক্ত তাপমাত্রার উপস্থিতিতে স্প্রিংকলার ফেটে জল ছড়িয়ে আগুন নেভায়) ও হোজ বক্স (কাচের বাক্সে লাল প্যাঁচানো নল, যা যুক্ত থাকে হাইড্রেন্টের সঙ্গে। যে তলায় আগুন লাগবে, সেখানে কাচের বাক্স খুলে প্যাঁচানো নলটি ৫-১০ ফুট সামনে নিলেই স্বয়ংক্রিয়ভাবে জল বেরোতে থাকবে, আগুন নেভাবে) যন্ত্র ব্যবহারের ওপর প্রশিক্ষণের ব্যবস্থা ও নির্দিষ্ট সময় পরপর মহড়ার ব্যবস্থা করা উচিত।
আমরা সবাই আসলে আগুনকে চিনি কিন্ত খুব কম লোকই আগুন সম্পর্কে জানি ।
চেনা আর জানার ফারাকটা কিন্ত ক্ষেত্র বিশেষে বিস্তর। তাই দয়া করে আগুনকে জানুন ।
আজকে থেকেই হোক আপনার জানার চেষ্টা ।


Saturday, February 23, 2019

NFPA 13 in High-Rise Buildings

NFPA 13 in High-Rise Buildings

Designing and installing fire standpipes and sprinkler systems in modern high-rise buildings properly requires in-depth analysis to ensure occupant safety.

High-rise buildings present several unique challenges not found in traditional low-rise buildings; longer egress times and distance, evacuation strategies, fire department accessibility, smoke movement and fire control.


Nearly 3,700 years ago, the responsibility of the stability of a structure was first bestowed upon building inspectors. The inspectors made sure that building materials were properly cut and made from unflawed components. When the inspectors deemed a stone to be of sufficient quality, they were authorized to affix the king’s seal to the stone. If subsequently a building collapsed and a sealed stone was found to be at fault, the inspector was at fault. This king was, of course, Hammurabi, the inspectors were the progenitors of today’s testing laboratories, and the rationales they used to determine the stone’s quality were the original standards.
High-rise buildings have garnered significant attention in the fire safety world over the years. The multiple floors of a high-rise building create the cumulative effect of requiring great numbers of persons to travel great vertical distances on stairs in order to evacuate the building. The public, code bodies, local, regional and federal governments, as well as the design, build, and ownership communities are all affected by high-rise building safety.

The 42 is a residential skyscraper in Kolkata in the state of West Bengal, India. It is currently the tallest building in India. It is located in Chowringhee, the central business district of the city.

The primary design and installation standard used in most of the U.S. for commercial fire sprinkler systems is NFPA 13 2019: Standard for the Installation of Sprinkler Systems. To properly use this standard to design or install a system, one must be familiar with the standards upon which it is based and those which it references. It is within these auxiliary standards that lurk the minefields that can explode with devastating effect. For example, one of the commonly misunderstood provisions of NFPA 13 is Section 6.1.1., which many believe requires that all materials and devices be listed. It does not.

NFPA 13 recognizes there are eminently acceptable materials, such as pipe, fittings, and valves, manufactured to other long-respected standards promulgated by the American Society for Testing and Materials (ASTM), the American Society of Mechanical Engineers (ASME), and the Manufacturer’s Standardization Society (MSS) of the Valve and Fittings Industry that, when properly selected and applied, will result in perfectly satisfactory strength, durability, and performance. In fact, the materials manufactured to these standards typically have ranges much more appropriate to today’s taller structures than do those listed to the arbitrary and archaic limit of 175 psi found in NFPA 13.
It is therefore important that the engineer designing the fire standpipes and sprinkler systems in modern high-rise buildings properly analyze the needs of the systems, determine the pressures to which the systems will be subject, and, through judicious application of the principles of the ASME Boiler and Pressure Vessel Code provisions found in ASME B31.1 and B31.9, select the pipe, fittings, and valves most suitable for the installation.

An equally important factor in materials selection is the system’s life expectancy. It must be determined, through conversations with the owner, user, and regulatory agencies, what the expectations are for the service life of the systems and their components as well as the building life they are protecting. This, coupled with the engineer’s knowledge of the environment into which they will be placed, allows for selection of materials and corrosion mitigation strategies that will assure an adequate service life, as not all materials are created equal and not all materials used in proximity to each other are compatible.

Blind reliance on listed materials bearing a mark from Underwriters Laboratories (UL) or Factory Mutual Global (FM Global) does not come close to satisfying the standard of care to which an engineer is held, nor does it assure there will not be legal arguments at some future date as to the adequacy of the materials selected. A simple example is the standard commercial riser manifold produced by most of the manufacturers that bears both the FM Global and UL marks and a molded or engraved pressure limit identifier of 175 psi. Upon detailed examination, it can be determined that many of these devices are clearly acceptable for pressures well in excess of 175 psi. However, they are only listed to 175 psi because the UL and FM Global standards under which they are listed arbitrarily chose this number from an oft-repeated pressure in NFPA 13. And, in fact, it is not possible in modern high-rise buildings to limit the pressure of the principal piping systems to 175 psi. Even though recent times have seen the inclusion of products listed at pressures up to 300 psi, such listings do not cover the full catalogue of needs, nor is 300 psi a magic bullet number any more than is 175 psi.

There is simply no substitute for doing an appropriate engineering analysis of system needs and specifying materials and devices that will meet the demands of that analysis. Mere reliance on the obvious provisions within NPFA 13, the listing directories of UL and FM Global and manufacturer’s catalogues written to satisfy the requirements of those documents is not adequate.

In preparing specifications, the engineer must be careful to specify only that which he needs and intends to enforce. Clauses such as “Comply with all applicable federal, state, and local codes and standards” don’t cut it. First, few engineers know what constitutes “all” of those applicable federal, state, and local codes and standards as they each have internal references to and adoptions of yet more codes and standards. Second, even fewer engineers have “all” of those codes and standards on their shelves; most of those who do have them are not aware of what is in them. And what is in Code A is not always compatible with the requirement of Standard B, though both are applicable and the more stringent will apply.

For example, NPFA 13 requires that to fully equip a building, sprinklers must be installed in all places that a fire could occur. An elevator machine room is such a space. However, ASME A17.1 Rule 102.2: Safety Code for Elevators and Escalators requires that electrical power to the equipment be shut off prior to the application of water. There is no direct connection between the response time and temperature rating of a heat detector and that of a sprinkler. The response time index (RTI) of a sprinkler is determined by what is known as the plunge test; there is no similar or equivalent test for a heat detector. Therefore, there is no way to reasonably comply with Section 21.4.1 of NPFA 72: National Fire Alarm and Signaling Code, which requires a heat detector be provided to respond appropriately prior to sprinkler activation. Feasibility requires a much more complex solution, especially when the intent of the code is taken into consideration.

One method of accomplishing the intent of these seemingly incompatible codes and standards would be to install a double interlock pre-action system within the elevator machine room and to require that one of the events necessary for the double interlock to release be the completion of the timing sequence for elevator recall. As elevator manufacturers will not permit direct monitoring of elevator circuitry to determine the initiation and status of recall, one must rely on a predetermined time and initiate that timer based on either smoke or heat detection within the elevator machine room. In the event of an actual fire, the other portion of the double interlock, the fusing of the sprinkler and consequent reduction in air pressure within the air-supervised pre-action system, will assure the presence of water in a timely manner when the electrically held valve is opened by the timing sequence.
Consulting or specifying engineer has a statutory first duty to preserve the public safety and a fiduciary duty to his client, normally the owner, it is an abrogation of those duties for the engineer to delegate responsibility to the design/build contractor, who is only required to comply with the lawful mandate of the local inspection authorities and has a fiduciary duty only to its ownership, by means of that all-too-commonly used bailout, “Contractor to provide and install a system complying with all applicable codes and standards.”
Ref: NFPA.org

Our Follower firesafetypunjab ask below question.
As discussed, NFPA 13 is an installation standard and does not specify which buildings or structures require a sprinkler system. NFPA 13 specifies how to properly design and install a sprinkler system using the proper components and materials after it has been determined that a sprinkler system is required. The administrative authority for requiring sprinklers within buildings rests with any of the following: the local building code; NFPA 5000, Building Construction and Safety Code; NFPA 101, Life Safety Code; International Building Code; or insurance regulations that typically specify which buildings and structures require sprinkler systems.

If you are using the strategies of the NFPA 101, Life Safety Code for an existing building, section 31.3.5.12 has an application for high-rise buildings.


Excerpt from 2015 NFPA 101 Existing Apartment Occupancies

Here are the references for the standards for installation:
Its most interesting that the building code deals with new construction not existing occupancies. Therefore the AHJ that is dealing only with the building code will naturally require new construction for renovations.

I can not speculate what the local building codes and regulations are for automatic sprinkler system.

Thanks to Milt Werner for correction.

Saturday, January 19, 2019

Fire Fighting Equipment Manufacturers in India 2018

Top Fire Fighting Equipment Manufacturers in India in 2018


The global fire fighting equipment market is projected to grow at a CAGR of 7.4% during 2017-2022. Fire safety systems and equipment market are anticipated to grow in the forecast period due to rising construction activities and growing awareness. Europe and North America have stringent regulations related to fire safety across all sectors. Fire sprinkler systems in the fire fighting equipment segment hold a major revenue share in the global market as these are installed in hospitality, retail and commercial sectors. The top 10 fire safety companies in India not only provide world-class safety and fire equipment but also fire security to many homes and commercial buildings.   The hospitality sector is one of the major application areas for fire safety systems and equipment and growing tourism sector would fuel the market growth as the construction of new hotels & resorts is anticipated to lead the way for fire fighting equipment list in coming years.   With increasingly stringent compliance requirements for manufacturing and service sector companies as well as real estate developers to install complete fire fighting equipment list, coupled with increasing frequency of consumer awareness programs and safety audits, demand for fire & safety equipment in India is expected to continue growing over the next five years. These top 10 fire safety companies in India ar one of the few companies to watch out for in 2018.

1. Ceasefire Industries Pvt. Ltd: Located in Noida, Ceasefire Industries Pvt. Ltd is one of the leading fire fighting equipment manufacturers in India, having been incorporated in 2002. With extensive investments in R&D, the company offers more than 400 products in the fire fighting and safety equipment list.

2. Safex Fire Services Ltd: Safex Fire Services Ltd is an eminent manufacturer, exporter, and supplier of different types of fire fighting equipment, founded in 1972 at Mumbai, India. The company has a golden reputation for superb after sales service and is well known to customize the high-quality products on offer.

3. Reliance Fire and Safety Limited: Reliance Fire and Safety Limited is another leading fire fighting equipment manufacturers in India. The company was established in 1996 at Secunderabad. The company has a team of well-qualified engineers and technicians with proven ability and track record in various types of fire fighting equipment.

4. UTC Fire & Security India Ltd: UTC is a global fire fighting equipment manufacturer, based out of Mumbai and operating since 1981. UTC Fire and Security India Limited manufactures, erects, installs, and commissions fire protection and security systems in India and internationally. The company operates through Fire Protection and Security, and Research and Development segments.

5. NewAge Fire Protection Industries Pvt. Ltd: NewAge Fire Protection Industries Pvt. Ltd is one of the oldest specialist firefighting equipment manufacturer in Asia. The company was founded in the year of 1960 at Surendranagar, Gujarat and it has more than 5 decades of experience of manufacturing of different types of firefighting equipment.

6. Safepro Fire Services Pvt. Ltd: Safepro Fire Services Pvt Ltd is one of the progressive firms in the field of firefighting equipment manufacturing, established in the year 2000 in Mumbai. The company is a renowned manufacturer of firefighting equipment and provides a wide range of fire, carbon dioxide fire, water fire, and foam fire extinguishers.

7. Usha Fire Safety Equipments (P) Ltd: Usha Fire Safety Equipments Private Limited was founded in 1990 at Chennai. The company is committed to serve the world by saving human life and property and to emerge as one of the market leaders with a large footprint in India by means of enhancing customer satisfaction.

8. Kanadia Fyr Fyter Pvt Ltd: The company has proven capability and installed capacity to produce high-quality industrial fire fighting equipment in a wide spectrum of different sizes and types. A brand of Kanex, the company was founded in 1986 in Mumbai and their products are made from the superior quality raw materials sourced from well-established and reputed vendors to ensure flawless manufacturing process.

9. SafeGuard Industries: Located at SIDCUL, Haridwar, SafeGuard Industries is a reputed enterprise offering firefighting equipment list that includes fire hydrants, fire hydrant system, fire extinguisher, fire sprinkler system, smoke detection & fire alarm System, gas flooding system. The company designs and manufactures a wide range of firefighting equipment that is demanded lightweight, robust construction, past clients served, and optimum performance.

10. ABC Fire India: The company is a supplier, manufacturer and service provider of firefighting equipment names that include fire hydrant testing, fire brigade equipment, fire sprinkler, firefighting equipment, and fire alarm. ABC Fire India is in Coimbatore, having been founded in the year 1997. The Company has been certified by CRISIL as a verified vendor and distributes and undertakes turnkey project works on fire alarm system, fire hydrant pipeline system, fire sprinkler system, fire suppression system, fire diversion system, automatic detection system, and supply and service of fire extinguishers to various corporate, industries, vehicles, and homes.


Sunday, December 2, 2018

Christmas trees placement within buildings

Christmas trees placement within buildings

We explain this through NFPA 1, Fire Code (2018 edition). 10.13 indicate Combustible Vegetation.

10.13.1 Combustible vegetation, including natural cut Christmas trees, shall be in accordance with Section 10.13.

10.13.1.1 Christmas tree placement within buildings shall comply with Table 10.13.1.1.

10.13.2 In any occupancy, limited quantities of combustible vegetation shall be permitted where the AHJ determines that adequate safeguards are provided based on the quantity and nature of the combustible vegetation.
10.13.3 Provisions for Fire Retardance for Artificial Vegetation.
10.13.3.1 Artificial vegetation and artificial Christmas trees shall be labeled or otherwise identified or certified by the manufacturer as being fire retardant.
10.13.3.2 Such fire retardance shall be demonstrated by each individual decorative vegetation item, including any decorative lighting, in an approved manner.
10.13.4 Vegetation and Christmas trees shall not obstruct corridors, exit ways, or other means of egress.
10.13.5 Only listed electrical lights and wiring shall be used on natural or artificial combustible vegetation, natural or artificial Christmas trees, and other similar decorations.
10.13.6 Electrical lights shall be prohibited on metal artificial trees.
10.13.7 Open flames such as from candles, lanterns, kerosene heaters, and gas-fired heaters shall not be located on or near combustible vegetation, Christmas trees, or other similar combustible materials.
10.13.8 Combustible vegetation and natural cut Christmas trees shall not be located near heating vents or other fixed or portable heating devices that could cause it to dry out prematurely or to be ignited.
10.13.9 Provisions for Natural Cut Trees.
10.13.9.1 Where a natural cut tree is permitted, the bottom end of the trunk shall be cut off with a straight fresh cut at least 1∕ 2 in. (13 mm) above the end prior to placing the tree in a stand to allow the tree to absorb water.
10.13.9.2 The tree shall be placed in a suitable stand with water.
10.13.9.3 The water level shall be maintained above the fresh cut and checked at least once daily.
10.13.9.4 The tree shall be removed from the building immediately upon evidence of dryness.
10.13.10 Exterior Vegetation.
10.13.10.1 Cut or uncut weeds, grass, vines, and other vegetation shall be removed when determined by the AHJ to be a fire hazard.
10.13.10.2 When the AHJ determines that total removal of growth is impractical due to size or environmental factors, approved fuel breaks shall be established.
10.13.10.3 Designated areas shall be cleared of combustible vegetation to establish the fuel breaks.



Sunday, November 25, 2018

Holidays Safety tips

Holidays Safety tips

Respect electricity at all times. Fire can be a good thing when treated with respect, but can be a danger when paired with the many distractions during the holiday season. So in the quest to create a good old-fashioned family celebration, follow these important safety tips:-

INDOORS
·         Is your tree live? If so, make sure it is fresh and green with needles that are hard to pull from the branches.
·         Place the tree in a stand with water, well away from heaters or the fireplace, and check the water daily.
·         Before putting lights on the tree or using them in other home decorations, examine them carefully. Do they have frayed wiring or loose sockets? Throw them out! Make sure any you keep or replace have been tested for safety by an independent testing laboratory.
·         Make sure all light sockets have bulbs in them. Children are fascinated by lights and could put their fingers in empty sockets.
·         Do not let bulbs touch tree branches. Never burn candles on or near the tree and never use flammable decorations.
·         Never use lights on a metallic tree. If the lights become faulty, the entire tree could be electrified.
·         Be careful not to overload extension cords, outlets or even whole circuits in the house.
·         For optimum safety as well as energy efficiency, use smaller, cool-burning LED lights.
·         Place wires where they cannot trip anyone. Do not run them under rugs.
·         Turn off decorative lighting when you leave the room.

OUTDOORS
·         Make sure the lights used are specifically designated for outdoor use and the cords are not worn or frayed.
·         Use a non-conducting fiberglass or wooden ladder when working with strings of lights, and stay clear of all overhead wires.
·         Turn the electricity off before replacing bulbs.
·         Never let light bulbs touch flammable materials such as plastic or dry grass and leaves.
·         For outside use, work only with three-wire grounded extension cords.
·         Use rubber gaskets in light sockets or hang sockets downward to keep water out.
·         Keep connections and lights off the ground by hanging them over wooden stakes.

Follow all safety guidelines to ensure that you and your family make happy memories and get to enjoy this time with those you care about most.
WINTER HOLIDAY FIRES
Christmas trees
·         Between 2012-2016, U.S. fire departments responded to an average 170 home fires that started with Christmas trees per year. These fires caused an average of 4 deaths, 15 injuries, and $12 million in direct property damage annually.
·         On average, one of every 45 reported home fires that began with a Christmas tree resulted in a death, compared to an average of one death per 139 total reported home fires.
·         Electrical distribution or lighting equipment was involved in 43% of home Christmas tree fires.
·         In one-quarter (27%) of the Christmas tree fires and in 80% of the deaths, some type of heat source, such as a candle or equipment, was too close to the tree.
·         More than one-fifth (22%) of Christmas tree fires were intentional. 
·         Forty-two percent of reported home Christmas tree fires occurred in December and 33% were reported in January. 
·         Two of every five (40%) home Christmas tree fires started in the living room, family room, or den.
Source: NFPA's "Home Structure Fires Involving Christmas Trees" report
Holiday decorations
·         U.S. fire departments responded to an estimated average of 800 home structure fires per year that began with decorations, excluding Christmas trees, in 2012-2016. These fires caused an annual average of two civilian fire deaths, 34 civilian fire injuries and $11 million in direct property damage.
·         Ten percent of decoration fires were intentional.
·         The decoration was too close to a heat source such as a candle or equipment in two of every five (42%) fires.
·         More than one-fifth (21%) of the decoration fires started in the kitchen. Fifteen percent started in the living room, family room or den.
·         One-fifth (19%) of the home decoration fires occurred in December. 
 
Candles
·         On average, 23 home candle fires were reported each day between 2012-2016.
·         More than half (56%) of the December home decoration fires were started by candles, compared to one-third (31%) in January to November.
·         The top three days for home candle fires were Christmas, New Year’s Day, and New Year's Eve.
 
Holiday cooking
·         Thanksgiving is the peak day for home cooking fires, followed by Christmas Day and Christmas Eve.
·         Cooking equipment was involved in 20% of home decoration fires. This can happen when a decoration is left on or too close to a stove or other cooking equipment.
 
Fireworks
·         Ten percent of fireworks fires occur during the period from December 30 through January 3, with the peak on New Year's Day.
Source: NFPA's "Fireworks" report.

Heating, holiday decorations, winter storms and candles all contribute to an increased risk of fire during the winter months.


Sunday, October 7, 2018

Fire Safety Training Programmes Should Be Refreshed

Fire Safety Training Programmes Should Be Refreshed

When it comes to the workplace, staff should receive fire safety training in order to know how to deal with a blaze. The training might take the form of learning about different signs, what to do in case of a fire, or how to use an extinguisher. Not only does fire safety training prepare staff for the worst case scenario, it enables them to become accustomed to the layout of a building.
The person trained should have a clear understanding of the overall duties and responsibilities. This will include: what action they should take on the discovery of a fire, know the difference between different fire classes, which extinguisher to use for which fire and what the evacuation procedure is. The person should be at-list 5yr in FSAI under valid individual membership or NFPA member. If person is ex service men of fire brigade or Fire protection officer that may consider extra.

But there comes a time when the fire safety training policy needs to be refreshed.


What is fire safety training?
If a fire breaks out in your workplace, the highest priority is to get everybody out of the building as quickly, efficiently and carefully as possible. However, no matter how many times people have been informed of the evacuation procedures and methods of fire protection and combat, the sound of a fire alarm can cause chaos and all sense of cognitive, reasonable action can be forgotten.


This is usually put down to the fact that an emergency situation unknown feelings and reactions that are stressful, intense and require an immediate response. However, fire safety experts believe that training, knowledge and practical experience can cause behaviour to be modified, preparing people for how to deal with a fire, and they suggest that this will lead to the best chance of a safe and methodical evacuation being conducted.

Understanding the Fire Triangle

A fire needs 3 elements in order for it to ignite – oxygen, fuel and heat – and a fire can be extinguished by removing one of these elements. For instance, covering a fire with a fire blanket removes the oxygen supply, therefore putting the fire out.

Discovering a fire (alarm and assembly points)
On discovering a fire, the first thing you should do is raise the fire alarm so everybody on the premises is aware there is a fire in the building. You should then ensure everyone safely exits the building and gathers at the appropriate assembly point.

Types of fires
Being a fire trainer / warden also entails having a basic understanding of the types of fires there are:
1)      Class A fires involve solid materials such as wood, paper, rubber, plastic and cloth.
2)      Class B fires involve flammable or combustible liquids, such as petrol, oil and paint.
3)      Class C fires involve flammable gases, such as propane, butane and methane.
4)      Class D fires involve flammable metals, such as potassium, aluminium and titanium.
5)      Class F fires involve cooking oils and fats.

Types of extinguishing agents
1)       Water (Red): Suitable for wood, fabric and paper.
2)       Foam (Cream) : Suitable for flammable liquids, wood and paper.
3)       Powder (Blue): Suitable for flammable liquids, gas, electrical hazards, oil and chemicals.
4)       CO2 (Black): Suitable for flammable liquids and electricals.
5)
       Wet chemical (Yellow) : Suitable for cooking fat and oils.


Identification of which fire extinguisher to use for which fire
1)      Water: Ideal for class A fires and office, shop or warehouse environments.
2)      Foam:  Use on class A or B fires on electrical or material based fires.
3)      CO2: Perfect for Class B fires like those caused by flammable liquids or electrical appliances.
4)      Wet Chemical: Ideal for kitchen related fires with cooking oils and fats involved.

How to use a fire extinguisher
1)       Pull the pin out.
2)       Aim the nozzle at the base of the fire.
3)       Squeeze the lever slowly.
4)       Keep at a distance and sweep the nozzle from side to side, moving closer as the flames decrease un till the fire is completely out.

People with disabilities
The Disability Equality Duty highlights that disabled people should not be discriminated against under any circumstance. Therefore, they should still be given an evacuation plan despite any differences in mobility. As such, the fire warden should be aware of those who may need extra assistance when evacuating and allow extra time for this so they are not exposed to any discrimination.


These steps outline some simple stages to training your staff in fire safety; however official training is required in order to guarantee a legitimate qualified fire warden will be on hand in the case of an emergency. The courses are available on-site or off-site, dependent on location, and the names of those who attended the course should be kept in a log book. It’s also recommended that you go on a refresher training course a year later to remind yourself of the procedures to ensure absolute safety to your fellow staff members.

We’ve listed five reasons why this should happen.


New staff
When you hire someone new, don’t assume that they understand basic fire safety. This should be included in the induction process, so it may be necessary to carry out a new training programme.

Fire safety training certificate expiration
Fire safety training certificates don’t last forever, so there will come a time when they’ll need to be updated. Refreshing the training programme will keep your staff up to date with the latest policies.




Building change
If you’ve moved to a new premises then it may have a different layout to the previous building. This will require you to carry out a new safety plan, safety assessment and training. The new building may also come with a different set of hazards, so knowing where the exits are should be included in the training.

New equipment
If new equipment has been installed then it’s recommended you re-train employees in how to use it, especially if the equipment differs from the previous technology.

Industry incidents
If an incident happened within the industry that applies to your business, then refreshing the fire safety programme may be relevant. Extra training could be provided to ensure that staff is up to date. As a general rule, fire safety training programmes should be refreshed every 12 months. We provide a range of fire safety services designed to help businesses.

Example Fire Safety Training Programme

All employees will receive adequate fire safety training and all fire safety training sessions will be delivered by a competent person.

There will one fire drills per year to test the fire safety training.


Fire Safety Training Sessions

New Employees:               Induction Programme

Current Employees:          One training session per year

Managers:                      One training session per year specific to their duties and including fire safety risk assessment, responding to fire hazards, fault reporting procedures, liaising with the fire service, record keeping, induction of new staff, fire safety policies and procedures.

Fire Safety Training Topics

-               The significant findings from the fire risk assessment and fire safety policies;
-               What to do on discovering a fire;
-        How to raising the alarm, including the locations of fire alarm call points (break glass points);
-               The action to take upon hearing the fire alarm;
-               The evacuation procedure for alerting guests, residents and visitors including, where
-               appropriate, directing them to exits and assembly points at a place of total safety;
-               The arrangements for calling the fire and rescue service;
-            The location and , where appropriate,  the correct use of portable fire extinguishers and fire-fighting equipment;
-               Knowledge of escape routes including stairways and especially those not in regular use;
-               How to open all emergency exit doors;
-            The appreciation of the importance of fire doors, keeping them closed and not wedged open to prevent the spread of smoke and heat, keeping escape routes unobstructed;
-               Where appropriate, isolating electrical power and gas supplies and stopping machines and processes;
-               The reasons for not using lifts (except those  specifically constructed as evacuation lifts);
-               The safe use of and risks from storing and working with highly flammable and explosive substances;
-               General fire precautions, fire awareness and good housekeeping practices;
-               The no smoking policy (where applicable);
-               Special provisions for assisting disabled people and any training needed;
-               Identifying fire hazards and fire incidents reporting procedures; and
-               Equipment fault reporting procedures.

Fire Safety Training Records


All fire safety training will recorded to include the date of instruction; the duration, name of the person giving the instruction, names of persons receiving the instruction; and the nature of the instruction and / or, drill.