Monday, February 1, 2021

Circuits and Pathways in NFPA 72

 Circuits and Pathways in NFPA 72

In Greece, over 2500 years ago, near the small town of Marathon, there was a battle. After the battle, one of the winning Athenians ran all the way from Marathon to Athens carrying the news.

He ran along a path.

Nowadays, the message could be carried by a person running along a narrow mountain road, a verbal telephone call, a news story over the microwave towers, a data signal carried over fiber optics, Etc.; so may choices.
The NFPA would consider all of these to be communication paths. The paths are no longer just copper wires, but wireless radio waves are also used, Ethernet data cables are also used, and fiber optic cables are also used in fire alarm systems.

Because of all the different types of communication paths for fire alarm systems being used nowadays, the NFPA is addressing them all differently than they did in the past.

Beginning with the 2010 edition of NFPA 72, National Fire Alarm and Signalling Code, all of the “styles” of circuits were deleted, and four “classes” were added. A new chapter, Circuits and Pathways, was added during the reorganization of this code. In the past, the styles only described the operation during an alarm or fault condition for initiating device circuits, notification appliance circuits and signalling line circuits. NFPA 72, National Fire Alarm and Signalling Code, defines the performance of fire alarm circuit and pathways in Chapter 12. While the terms “circuit” and “pathway” are often used interchangeably, they are different. The styles of initiating device circuits (IDC), notification appliance circuits (NAC) and signalling line circuits (SLC) were eliminated, and four new classes were added. The intent was to add information about all circuits and pathways, not just IDCs, NACs and SLCs. A circuit is defined in Chapter 3 as “either means of providing power or a connection path between locations”, while a pathway is “any circuit, conductor, optic fiber, radio carrier or other means connecting two or more location.” Basically, a circuit is copper, while a pathway can be copper or any other type of connection.

There are three things considered by the NFPA with the carrying of the signals on the fire alarm system paths:

1.    Supervision - The method of self-checking for faults - the end-of-line resistor continuity check and handshaking using data signals are two common methods

2.    Redundancy - the continued operation of the whole fire alarm system, or a second path to carry signals around a problem is redundancy - an open wire or wire-to-wire short are some of the problems addressed with redundancy

3.    Protection from damage - conduit is one common method used to protect the path

Pathway performance is defined in Section 12.3, using Class A, B, C, D, E, N, or X based on the circuit performance. NFPA 72 does not determine what class is used on a particular pathway, but rather defines the performance of the pathway. The specification, designer, AHJ determine what class of pathway is used. NFPA 72, Chapter 24, “Emergency Communications Systems,” Section 24.3.14 is the only place I have found any requirements for survivability. Survivability for fire alarm pathways is typically only required for systems employing partial evacuation or relocation. Since building and fire codes require systems to be installed in accordance with NFPA 72, they do not have specific provisions for survivability. The Chapter 24 technical committee is proposing important changes to the 2022 edition of the code.

A pathway classification describes more than that. When describing a Class, the NFPA is concerned with is Reliability, Fixability, and Survivability.

Reliability - The NFPA wants to make sure the fire alarm system continues to work in the long run.

Fixability - The NFPA wants to make sure any problems that do occur are found and fixed on a timely basis.

Survivability - The NFPA wants to make sure the fire alarm system will continue to work when fixing it on a timely basis isn't good enough.

In a fire alarm system, there are (at the moment) seven Classes of communication and power infrastructure (paths):

  • Class A
  • Class B
  • Class C
  • Class D
  • Class E
  • Class N
  • Class X

The letters after the word Class are not shown in the order of reliability or importance; the letters after the word Class are only the name of the particular classification.

Chapter 12 describes each class. Here are some examples of each you may find useful.

 

Class A

1.    This will include a redundant signal path - If the path is interrupted, the system feeds both ends of the paths so there are now two paths; the original outgoing path which is now cut shorter, and the return path which is now being used as an outgoing path

2.    If wires are used, a wire-to-wire short may shut down the whole path

3.    Both conventional and addressable systems fit into this

4.    Both the IDC (Initiating Device Circuit) and the NAC (Notification Appliance Circuit) fit into this

5.    The panel shows a trouble signal when there is a problem

Class B

1.    There is no redundant path

2.    Any device beyond a break won't work

3.    If wires are used, a wire-to-wire short may shut down the whole path

4.    Both conventional addressable systems fit into this

5.    Both IDC and NAC fit into this

6.    The panel shows a trouble signal when there is a problem

Class C

1.    Uses Handshaking (equivalent to an I'm OK signal) to supervise the path

2.    Can have more than one pathway

3.    The panel shows a trouble signal when there is a problem 

 Examples:

1.    Signals from the fire panel to the monitoring company

2.    The use of IP (Internet Protocol), whether it's local communications or over the Internet

3.    The communicators over the telephone lines that are still in use

 

Class D

1.    Fail-Safe operation - If there is a failure, the device that is controlled by the fire alarm system goes into fire mode

2.    No trouble shows on the panel

Prior to the 2010 edition of NFPA 72, Class D pathways simply referred to as “fail-safe.” A typical application for a Class D pathway is a powered relay used for door release or fan control. Since the relay is powered in normal condition, operation of the relay is accomplished by removing power by control panel operation, or by a failure of the circuit.

 Example of a device going into fire mode when a wire breaks or a signal is lost:

1.    The fire door closes

2.    Emergency door locks release

3.    The damper closes

4.    The fans shut down

 

Class E

Class E pathways are not monitored for integrity and are used in applications where supervision is not required. Section 12.6 of NFPA 72 defines applications where monitoring for integrity is not required. Some examples include interconnection between equipment in an enclosure, interconnection between control equipment within 20 feet of each other where conductors are protected by conduit, and interconnection wiring of a stationary computer to its keyboard, monitor, or mouse where the wiring does not exceed 8 feet.

Class N

This is basically local Ethernet, Token Ring, or other network or IP infrastructure.

1.    Unless a single device is connected, or the path is short (less than 20 feet) and really protected in something like conduit, two pathways are used

2.    These pathways are verified through end to end communication, like data handshaking

3.    Loss of communication between end points on any path show a trouble signal on the panel

4.    Problems with one pathway won't affect the other pathway

Class X

1.    This will include a redundant signal path. Like Class A, if the path is interrupted, the system feeds both ends of the circuit so there are two circuits, the original outgoing path which is now cut shorter, and the return path which is now being used as an outgoing path

2.    Devices on both sides of an open will continue to communicate with the panel

3.    If wires are used, devices on both sides of a wire-to-wire short will continue to communicate with the panel (basically the short has to be isolated on both sides of the short)

4.    The panel shows a trouble signal when there is a problem

In order to be proper classified as Class A or Class X, the outgoing and return path routes for both Class A and Class X have to be separated by a certain distance; the two paths cannot be inside the same conduit, for instance.

Many designers and contractors do not include survivable cable or fire-rated enclosures in their designs for in-building fire emergency voice/alarm communications systems (EVACS) wiring as required in the code—or at least not until the authority having jurisdiction enforces the requirement because a designer missed it the first time around. This may be due in part to some confusion over where survivability is required in the first place. Pathway survivability is not required for all EVACS; it is only required where occupants will remain in the building during an emergency (i.e., relocation or partial evacuation). The intent is to ensure that we can still get subsequent instructions to those occupants if the situation worsens. For those systems where pathway survivability is required, it does not necessarily need to be applied throughout the entire system; it must be applied only where the circuit runs through multiple notification zones, so that a fire in one notification zone doesn’t impair the ability to communicate with occupants in another. Additionally, the current edition of NFPA 72 permits the installer to use Level 1, Level 2, or Level 3, meaning that a sprinklered building (i.e., Level 1 pathway survivability) does not require the use of fire-resistant cabling or an enclosure. No wonder a contractor or installer might not include fire-resistive cable in an initial design.


The reason behind survivability requirements is to maintain the operational reliability of the EVACS during a fire. Pathway survivability for emergency communications systems (including EVACS) is covered in 24.3.14; Section 12.4.5 includes the definition of Level 4 pathway survivability.
The previous requirements for survivability said only that the cable had to be two-hour-rated or installed in a two-hour-rated enclosure. The technical committee changed the requirement so that it is now related to the fire resistance rating of the building construction. This relationship is important because the listing of two-hour fire-rated cable is required to be attached to a concrete wall or floor assembly, constructed with a minimum of two-hour rating or as otherwise identified by the UL FHIT systems assembly.

Additionally, as stated in the Annex A of the code, “installing a pathway survivability Level 2 or Level 3 in a building that is constructed with less than two-hour construction would not be installed within the listing of the product.”

For building construction with a fire-resistance rating of one hour, but less than two hours, the technical committee has proposed a new Level 4 pathway survivability.

With the more common use of timber construction for larger buildings, the expectation is these buildings would be classified as one-hour fire rated. Two-hour cable, as it is presently listed, would not be allowed when using the proposed Level 4 wiring or with wiring that meets the proposed separation requirements. That prohibition is due to the concern that a fire causing an open, ground-fault, or short-circuit fault on the communication and control circuits between rooms or enclosures could affect the operation of the in-building fire emergency voice/alarm control equipment within these rooms or enclosures.

It is well known that the insulation on fire alarm cabling can melt when exposed to heat and flames, causing the conductors to short circuit. When this condition occurs, it is possible for an entire signaling line circuit to fail, seriously impacting communication and control circuits. To help guard against these kinds of catastrophic failures, the proposed code would require the use of fault circuit isolators to ensure that the entire circuit is not disabled during a fire.
These proposed changes to the 2022 code would provide guidance in Annex A to assist designers, contractors, and AHJs in the proper separation of circuits as well as the location of fault circuit isolators to ensure both compliance with the code and a high degree of operational reliability. It is important to remember that for fire alarm systems designed for relocation and partial evacuation, communication must remain operational on all floors other than the fire floor during a fire. The primary fire protection goal is reliable communication during the fire.


Friday, February 4, 2011

BASIC FIRE SCIENCE

BASIC FIRE SCIENCE

A.   FIRE TRIANGLE
Four things must be present at the same time in order to produce fire:
 
1.    Enough oxygen (O2) to sustain combustion,
·         Oxygen (O2) is an element from the atmospheric air that supports the combustion process.  It makes up 21% of the total air mixture.
2.    Enough heat to raise the material to its ignition temperature,
·         Heat is a form of energy which may be produced by mechanical or chemical reaction and transmitted via radiation, conduction and/or convection.
3.    Some sort of fuel or combustible material,  
·         Fuels are combustibles that may exist in solid, liquid, molten and/or gaseous states. Examples of fuels are paper products, wood products, molten chemicals, flammable fluids and gases.
4.    The chemical, exothermic reaction known as fire.

Fire occurs when fuel and oxygen come into contact with substantial amount of heat energy. This will cause a chain reaction to take place which will in turn produce sufficient heat energy to propagate the burning in the presence of subsequent fuel and oxygen.

Oxygen(O2), heat, and fuel are frequently referred to as the "fire triangle." Add in the fourth element, the chemical reaction, and we actually have a fire "tetrahedron."


Combustion will continue as long as all these factors are present. Removal of one of the factors will lead to the collapse of the "triangle/ tetrahedron" and combustion stops, and we will not have a fire or the fire will be extinguished.
B.   METHODS OF EXTINGUISHING FIRE
Fire Safety, at its most basic, is based upon the principle of keeping fuel sources and ignition sources separate.

Fire can be extinguished with one or a combination of the following methods:
 
1.    Starvation: Removal of the combustible substances.
 
2.    Smothering: Limiting the amount of oxygen (O2) that supports combustion.
 
3.    Cooling: Reduce the temperature to the point of fire extinction.
 
4.    Breaking (blocking) or interfering with the chemical reaction occurring in the flame.
  
C.   BASIC STAGES OF FIRE DEVELOPMENT
Fir
Fires can be commonly seen to develop in the following stages:
1.    Initial
The fire develops from its point of origin. If the combustion reaction is capable of emitting further heat in the presence of subsequent fuel and oxygen, the reaction will propagate and temperature will continue to rise.
 
2.    Flashover
This is the transition stage between the Initial and the full development stage. The fire spreads rapidly and large merged flames are produced. Flashover will especially occur in a confined space fire.
 
3.    Full
Fire will be fully developed burning at/near its development maximum intensity.
 
4.    Decay
Fire is slowing down due to depletion of Oxygen and/or fuel. Introduction of subsequent Fuel and/or Oxygen will however propagate a second initial development.

D.   CLASSIFICATION OF FIRE
The different types of fire are classified into the following "Classes":
 
1.    Class A : For fires involving the burning of ordinary combustible materials like wood, paper, cloth, furnishing, plastics and rubber.
 
2.    Class B : For fires involving flammable liquids, solvents, oils, paints, thinner and flammable gases.
 
3.    Class C : For fires involving live electrical equipment like electrical mains, transformers and electrical appliances, etc and where extinguishing medium used must be electrically non-conductive. (If the electrical equipment is de-energised, extinguishers for Classes A and B can be used.)
 
4.    Class D : For fires involving combustible metals, eg. Potassium (K), magnesium(Mg), titanium(Ti), sodium(Na), lithium(Li) and zirconium.

 E.   IGNITION AND COMBUSTION

1.    IGNITION
 
i.      Ignition is the process of starting a combustion process through the input of energy.  
 
ii.     If the substance is a liquid, ignition can only occur when
·         There exists a gas/air mixture whose composition lies within the flammable range for that substance. A small ignition source, e.g. a spark or small flame, will then start ignition.
·         Enough vapour is given off the vapour surface so that a vapour/air mixture is formed whose properties lie within the flammable range for that substance. The flash point is the temperature at which the liquid gives off just enough vapour to form this flammable vapour/air mixture. For temperatures above the flash point a small igniting source will start ignition.
 
iii.    If the substance is a solid, ignition will only start when either:
·         The solid is heated so that destructive decomposition starts and flammable vapours are given off. When these vapours form a flammable vapour/air mixture combustion can be started if a small flame is applied. Most organic materials will come under third category. The size of ignition source needed will depend on the physical form and shape of the material. If it is in the form which has a high surface area to mass ratio only a small igniting source is required.
·         The solid is heated in air so that the surface oxidation is initiated of sufficient vigour to be self-sustaining reaction. Carbon and most metals are examples f this type of combustion. A high surface area to mass ratio is needed for ignition and this means that the metal has to be in he form of finely divided powder. An intense source of heat is required in most cases to ignite solids which burn this way.
 
 
2.    COMBUSTION
 
i.      Combustion is a reaction between a substance and oxygen in which heat is given out, i.e. it is an exothermic reaction, and enough heat must be given out either to maintain the temperature of the reactants or to continuously increase their temperatures so setting up a chain reaction.
 
ii.     In some cases the reaction between a substance and oxygen requires heat to be applied to maintain the reaction and the reaction stops when the applied heat is removed, this is not combustion.
 
iii.    All combustible materials burn as vapour phase reactions, i.e. they are reactions between two gases, one of which is usually oxygen. The combustible materials which are usually solid will, because of high temperatures involved, either melt and then vapourise and burn, or decompose by pyrolysis and give off flammable vapours which will then burn. There are exceptions and there can be reactions between oxygen and solid surfaces which are vigorous and exothermic and so can be termed combustion, e.g. carbon and certain metals. Liquids also vapourise before combustion takes place.
 
iv.   The following are the products of a combustion process:
 
Thermal           -           Flame & Heat
 
Non-Thermal   -           Smoke & Gases
 
·         Damage to property is due mainly to thermal effects although smoke and gases can also cause considerable damage. Some of the gases produced during combustion are corrosive, or become corrosive in solution with water.
 
·         Most fire deaths or injuries, however, may be attributed to smoke or gases arising from smoke inhalation and suffocation. Smoke can also cause panic among occupants which is likely to cause further injuries and death. Heat and flamers are primary causes of fewer deaths or injuries than smoke or gases.
 
·         The heat generated in the process of combustion can completely destroy a building. Steel will have lost two-thirds of its strength by the time it has been heated to 600 ° C. This is by no means uncommon temperature in a domestic fire. Concrete is more resistant material; but as reinforced concrete depends on steel for its tensile strength, there needs to be sufficient insulation of the steel to prevent it reaching its critical temperature. Timber, of course, burns but is a very good structural material as burning occurs at a fairly constant rate and so structural timbers can be oversized to provide a known measure of fire resistance. Bricks provide one of the best fire-resistant materials as they have already been kiln-fired at high temperature during manufacture.

Sunday, January 23, 2011

CLASSIFICATION OF FIRES

CLASSIFICATION OF FIRES

Fires are classed according to fuel and most effective extinguishing agent.

Class A
Fire involving common combustion material and which can be extinguished by use of water or water solution in form of jet and spray e.g. materials include wood, wood based material, cloth, rubber, and certain plastics.

Class B
Fires involving flammable or combustion liquids, paints, varnishes, greases and similar products, either miscible or immiscible with water.
Extinguishing agents include water spray, foam, carbon dioxide and dry chemicals.

Class C
Fires that involve gases or liquid gases in the form of a liquid spillage or a liquid or gas leak. Gases include methane, butane etc.
Foam or dry chemicals may be used to control class c fires involving shallow liquid spills, water in the form of spray is used to cool the containers.

Class D: 
Fires that involve combustion metals, e.g. sodium, magnesium etc.
Extinguishing agents like water, CO2 and bicarbonates are infective and hazardous if used.
Powered graphite, powered talc, soda ash, limestone and dry sand are normally suitable for extinguishing class d type fires.


Class K:
Class K fires involve combustible cooking media such as oils and grease commonly found in commercial kitchens. The new cooking media formulations used form commercial food preparation require a special wet chemical extinguishing agent that is specially suited for extinguishing and suppressing these extremely hot fires that have the ability to reflash.

Electrical Fires
Electrical fire by itself does not constitute a class since any fire involving or started by electrical equipment will be a fire of class a, b, c or d.
In case of a fire involving electrical equipment, electricity supply to the respective equipment must be cut off and an extinguishing medium appropriate to what is burning must be used.

NOTE: Although ABC and BC Dry Chemical extinguishers can control a fire involving electronic equipment, the National Fire Code (NFPA 75-1999 edition), Section 6-3-2, specifically advises against dry-chemical extinguishers for fires involving computers or other delicate electronic equipment due to the potential damage from residues.

Standard for the Protection of Electronic Computer/Data Processing Equipment

6-3.2 Listed extinguishers with a minimum rating of 2-A shall be provided for use on fires in ordinary combustible materials, such as paper and plastics. Dry chemical extinguishers shall not be permitted."

Class F:
New class specifically dealing with high temperature (  360°C) cooking oils used in large industrial catering kitchens, restaurants and takeaway establishments’ etc. Cooking oil fires, because of their high auto-ignition temperatures, are difficult to extinguish.

Conventional extinguishers are not effective for cooking oil fires, as they do not cool sufficiently or may even cause flash back, thereby putting the operator at risk.  These extinguishers contain a specially formulated wet chemical which, when applied to the burning liquid, cools and emulsifies the oil, extinguishing  the  flame,  sealing  the  surface  and preventing re-ignition.