WET ALARM VALVE
WET ALARM VALVE: If we answer the question of what is a Wet Alarm Valve; Designed for applications where water is not likely to freeze. Pressurized water in the pipes is discharged to the fire area as a result of the sprinkler being activated due to the fire. While the pressurized water system is fed continuously, it also fills the delay cell at the same time. After filling the cell, the pressure switch on the cell is triggered. The pressure switch transmits alarm information to the fire alarm system or automation system. After the pressure switch is triggered, the water reaches the water motor gong and provides a mechanical alarm. This system is designed for heated volumes and needs where the water does not fall below +4 °C and does not freeze. Alarm check valve or water flow detector are used to give mechanical and electronic alarms.
WHAT IS A WET ALARM VALVE AND WHAT ARE THE GENERAL
FEATURES?
Wet alarm valve is used in wet type fire extinguishing systems. It is used for applications where the water is above freezing temperature, ensuring that the pressurized water in the pipes is delivered to the fire area as a result of the sprinkler being activated in the event of a fire.
·
The
water, which is pressurized in the pipes, is discharged to the fire area as a
result of the sprinkler activation.
·
Pressurized
water fills the delay cell at the same time as the system is fed continuously.
·
After
the cell is full, the pressure switch on the cell is triggered.
·
The
pressure switch transmits alarm information to the automation system.
· Water reaches the motor gong and provides a mechanical alarm.
KEY FEATURES
Especially
in wet type sprinkler systems, automatic sprinkler is fixed to pipe systems
that are connected to a water source and contain water. In these systems, the
sprinkler opens with the effect of the heat generated by the fire, and they
allow the water to start pouring onto the burning materials. The effect of the
heat from the fire activates any sprinkler connected to the system and ensures
the flow of water. The released water is scattered by hitting the reflector in
the sprinkler and is discharged into the fire area in the form of a smooth
sprinkler. Depending on the conditions in the area of use, sprinklers are
designed to activate at a specified temperature between 40°C and 350°C. Most
sprinklers discharge approximately 70 to 100 liters of water per minute into
the fire scene.
The wet
sprinkler system can be divided into zones fed from a common column. The system
zone size is determined depending on the fire hazard class of the building. In
high storage areas, the maximum floor area on each floor connected to any feed
column should not exceed 3716 m². If a sprinkler zone addresses multiple floors
or separate occupancy zones, a traceable shut-off valve, flow switch, and test
and drain valve should be installed at the entrance to the floors or zones. In
the wet pipe sprinkler system, the pipes are kept constantly filled with
pressurized water. It is applied only in places where there is no risk of
freezing and the ambient temperature does not exceed 95 °C.
Experiences are taken into account regarding people’s safer lives in their living spaces. In this way, different standards and processes are created. The fire code standards applied in this way also include a certain system. In this system, the wet alarm valve takes on the biggest task. Due to its working principles, it ensures that the sprinkler system, which is the first responder to the fire, works effectively and smoothly. These valves, which act like a kind of heart, are responsible for activating the entire extinguishing system. Similarly, there is a dry alarm valve in check valves. However, their working principles are different. Valves used for wet areas should always have the principle of working smoothly and appropriately within the system. Wet alarm valves are used in areas where the water is not likely to freeze. It gives both mechanical (with engine gong) and electrical (pressure switches) alarms with the direction of the trim set due to the pressure difference created by the activation of the sprinklers during the fire. Can be used with delay cell to prevent false alarms.
PRODUCT INFORMATION
Wet Alarm
Valve is a check valve used in wet pipe sprinkler systems to activate
electrical and mechanical alarms with water flow from one or more opened
sprinklers. Wet alarm valve operating principle As long as the water pressure
in the sprinkler installation is equal to or more than the supply water
pressure, the alarm valve is in the closed position. By opening one or more
sprinklers, the wet alarm valve flap opens and water starts flowing into the
system and delay chamber. When the delay chamber is completely filled with
water, the pressure switch and the water alarm gong are activated by the water
pressure. After the fire is brought under control, the water flow to the area
can be stopped by closing the shut-off valve in the wet alarm valve station of
the area where the sprinkler is opened.
In
particular, one wet alarm valve should be used in each wet pipe sprinkler zone.
A shut-off valve should be placed below each alarm valve. Moreover, if the
sprinkler alarm valves are fed from the ring main supply line arranged inside
the building, the main supply ring should be divided into zones with regional
control valves. In addition, it is allowed to feed to a maximum of 4 alarm
valves from each part of the ring. The diameter of the alarm valve should be
selected according to the diameter of the fire zone installation column, which
is determined by hydraulic calculation.
These valves, which can control both electricity and mechanics, are of vital importance in fires. In particular, the wet alarm valve in the check valves group has an important place in the sprinkler system. It is also important to adjust the water pressure as needed. The valve remains closed when the pressure is equal or greater. If one or more sprinklers are opened, the clamp of the wet alarm valve is also opened and water flow to the required cells begins. At this time, the water alarm gongs are activated by the prosostat with the water pressure created. In other words, alarm valves start to work functionally. When the fire goes out or the situation in question disappears, the shut-off valve is closed from the station and the water going to the area is stopped. This system is very useful and will allow quick intervention until the teams arrive.
What is Wet Alarm Valve and Its Uses
1.
Warehouses
2.
Workshops
3.
Hospitals
4.
Living
Centers
5.
High-Rise
Residences and Residences
6.
Factories
7.
Homes
8.
Hospitals
9.
Schools
and universities
10.Hotel and dormitory buildings
11.Shopping malls
12.Cafeteria and restaurants
Nfpa 13 - What is the Alarm
Government Valve - Wet Pipe ? 👉🏻👈🏻
1. Warehouses
2. Factories
3. Hospitals
4. Shopping malls
5. Skyscraper structures and residences
When the fire fighting system starts increasing pressure, water will flow into the system until reaching a balance between the water supplying with the system pressure. And the alarm check valve can put pressure on the fire pumps valve to prevent the water backflowing. Once the pressure comes to balance, the alarm check valve will be in operation state, and the middle chamber of its seat ring will be sealed. So if the alarm check valve was set at maintenance state, there will no alarm port to the alarm facility (alarm pressure switch).